Comparative Analysis of Displacements and Stress Produced by Square and Rectangular Bracket Slot With Incremental
Sarvajith B Harsha1, Khadeer Riyaz1, Laxmikanth S Manjappa1
1Department of Orthodontics and Dentofacial Orthopedics, The Oxford Dental College, Bengaluru, IND.
Introduction:
This study aimed to perform a comparative analysis of stresses and displacements with incremental torque on the maxillary incisors and surrounding cortical bone using conventional metal brackets with rectangular slots and passive self-ligating brackets with square slots using finite element analysis (FEA).
Materials And Methods:
An in vitro FEA study was conducted, in which a three-dimensional (3D) model of the maxilla was built using ANSYS software version 18 (ANSYS Inc., Canonsburg, PA). The conventional McLaughlin, Bennet, and Trevisi (MBT) bracket (3M Unitek, Monrovia, CA) of 0.022 × 0.028-inch slot with a 0.019 × 0.025-inch rectangular stainless steel (SS) archwire (model 1) was compared with the Pitts 21™ self-ligating bracket system (OC Orthodontics, McMinnville, OR) of 0.021 x 0.21-inch slot with a 0.020 × 0.020-inch square SS archwire (model 2) at incremental torques of 5°, 10°, 15°, and 20°. The von Mises stress was evaluated at the maxillary incisors and surrounding cortical bone. The torque moment, tipping angle, and displacement of the maxillary incisors were also measured and compared between the bracket systems.
Results:
The highest torque expression of 13.8 N-mm was observed in model 2, compared to a torque expression of 10.68 N-mm in model 1. The torque expression increased in both models from 0°to 20°. There was a play of 6.2°at 20°torque in model 2, whereas it was 9.32°play in model 1. The torque expressions were better for the lateral incisors than for the central incisors. Increased incremental torque was associated with increased proclination of the incisors, and this movement was more pronounced for the central incisor and model 1. Furthermore, it was revealed that the stresses on the cortical bone and teeth were higher in model 2 than in model 1.
Conclusion:
It was concluded that the Pitts 21™ passive self-ligating system produced better torque expression and less play with square SS archwire compared to conventional brackets with rectangular SS archwire.
Related Concept Videos
Stress Concentrations in Circular Shafts
Residual Stresses in Circular Shafts
Torsion of Noncircular Members
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Design of Transmission Shafts - Stress Analysis
Stresses in a Shaft
Applying equilibrium conditions to the QR segment establishes that the internal shearing forces within the...