Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
An energy-conserving dose summation method for dose accumulation in radiotherapy
1Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA.
Background:
Radiation therapy often requires the accumulation of doses from multiple treatment fractions or courses for plan evaluation and treatment response assessment. However, due to underlying mass changes, the accumulated dose may not accurately reflect the total deposited energy, leading to potential inaccuracies in characterizing the treatment input.
Purpose:
This study introduces an energy-conserving dose summation method to calculate the total dose in scenarios where patients experience changes in body mass during treatment.
Methods And Materials:
The proposed method transfers dose and mass data from dosimetry images, where the delivered doses were calculated, to a reference image using an energy and mass-conserving dose reconstruction technique. The reconstructed dose assumes the same resolution and dimension as the reference image. The transferred masses are averaged at each image voxel in the reference image to generate an average mass. The transferred doses are then adjusted by multiplying by the ratio of their transferred mass to the average mass, and subsequently summed to calculate a mass-weighted (MW) total dose at each voxel. This method is demonstrated with a case of lung cancer retreatment.
Results:
The MW total dose was shown to be equivalent to the total deposited energy divided by the average mass. In the lung cancer retreatment case, the energy derived from the MW total dose was consistent with the sum of energy transferred from two treatments across all evaluated organs.
Conclusion:
The MW dose summation method can produce a total dose that accurately reflects the total energy deposited in each organ. The consistency may provide a robust foundation for verifying dose accumulations in adaptive radiotherapy.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Absorption of Radiation
The Power Superposition Principle
Energy Associated With a Charge Distribution
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...