Abstract:
The combination of two spectrometers in dual-laser Raman devices without the need for moving parts represents a significant advancement. This study focuses on design and fabrication of a dual spectrometer with no moving components, allowing data to be gathered using a single detector. This instrument consists of two Czerny-Turner optical arrangements which is symmetrically merged. Dual spectrometer single detector has two light inputs, each of them, concentrating the light separately on a one linear charge-coupled device detector through two independent optical paths. In this innovative spectrometer design, no optical moving parts are used, and therefore, the wavelength displacement error in repeating the spectroscopic experiment is zero. The independent nature of the optical paths enables the optimization of each spectrometer arrangement without affecting the other. The final spectrometer has a spectral resolution of 4.6 and 6.11 cm- 1 for Full Width at Half Maximum across the wavelength ranges of 532 to 708 nm and 784.65 to 1100 nm, respectively. Switching between the two different acquisition setups can be done seamlessly and quickly, with the ability to record approximately 2000 spectra per second. Standard neon and mercury-argon lamps' atomic radiation spectra, along with Raman scattering data from a cyclohexane standard sample, were successfully recorded using laser wavelengths of 532 nm and 784.65 nm.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...