Related Experiment Video
Updated: Jul 5, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Effect of different polishing systems on surface roughness and gloss values of single-shade resin composites
Hanife Altınışık1, Esra Özyurt2
1Department of Restorative Dentistry, Faculty of Dentistry, Gazi University, Emek, Ankara, 06510, Turkey. hanifekamak@gazi.edu.tr.
Background:
The aim of this study was to evaluate variations in the surface roughness and gloss of different single-shade resin composites after polishing with a range of systems.
Methods:
In total, 120 specimens were prepared from three different types of single-shade resin composites (supra-nanospherical-Omnichroma, nanohybrid-Charisma Diamond One, and microhybrid- Essentia Universal). The specimens were placed in distilled water and stored at 37 °C for 24 h. Each resin composite (n = 40) was divided into four groups (n = 10) according to the finishing/polishing (F/P) system: Mylar strip (control), Sof-Lex (multi-step), Twist Dia (two-step), and OneGloss (one-step). Surface roughness and gloss were measured. Surface characteristics were evaluated by atomic force microscopy (AFM) and a scanning electron microscope (SEM). A two-way analysis of variance (ANOVA) and Tukey's honestly significant difference test were used for statistical analysis (p < 0.05).
Results:
Among all the composites, both the highest surface roughness and lowest gloss values were obtained in the groups treated with the OneGloss polishing system (p < 0.05). Compared with all the composites, Omnichroma had the lowest surface roughness and highest gloss values (except Twist Dia) both unpolished and after polishing with all the F/P systems (p < 0.05). All composites treated with the Twist Dia F/P system had similar gloss values. The results of the AFM and SEM analyses were consistent with the surface roughness measurements.
Conclusions:
The gloss values of both the microhybrid and nanohybrid composites after F/P using the two-step system was superior to that of the traditional multistep system. The surface of the supra-nanofilled resin-based composite was smoother than that of both the microhybrid and nanohybrid composites.