Related Experiment Video
Updated: Aug 4, 2026

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy
Published on: January 29, 2018
Time is brain: detection of nonconvulsive seizures and status epilepticus during acute stroke evaluation using
Kapil Gururangan1, Richard Kozak2, Parshaw J Dorriz3
1Department of Neurology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA; Department of Neurology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA.
Objectives:
Seizures are both a common mimic and a potential complication of acute stroke. Although EEG can be helpful to evaluate this differential diagnosis, conventional EEG infrastructure is resource-intensive and unable to provide timely monitoring to match the emergent context of a stroke code. We aimed to evaluate the real-world use and utility of a point-of-care EEG device as an adjunct to acute stroke evaluation.
Materials And Methods:
We performed a retrospective observational cohort study at a tertiary care community teaching hospital by identifying patients who underwent point-of-care EEG monitoring using Rapid Response EEG system (Ceribell Inc., Sunnyvale, CA) during stroke code evaluation of acute neurological deficits during the study period from January 1, 2020 to December 31, 2020. We assessed the frequency of seizures and highly epileptiform patterns among patients with either confirmed strokes or stroke mimics.
Results:
Point-of-care EEG monitoring was used in the wake of a stroke code in 70 patients. Of these, neuroimaging and clinical information resulted in a diagnosis of stroke in 38 patients (28 ischemic, 6 hemorrhagic, 4 transient ischemic attack; median NIHSS score of 6.5 [IQR 2.0-12.0]) and absence of any stroke in 32 patients. Point-of-care EEG detected seizures and highly epileptiform patterns in 6 (15.8 %) stroke patients and 11 (34.4 %) stroke-mimic patients, including 2 patients with persistent expressive aphasia due to repeated focal seizures.
Conclusions:
Point-of-care EEG has utility for detecting nonconvulsive seizures in patients undergoing acute stroke evaluations.