Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

763
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
763
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

191
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
191
Atomic Nuclei: Types of Nuclear Relaxation01:28

Atomic Nuclei: Types of Nuclear Relaxation

262
Nuclear relaxation restores the equilibrium population imbalance and can occur via spin–lattice or spin–spin mechanisms, which are first-order exponential decay processes.
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers...
262
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

673
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
673
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

1.0K
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.0K
Downsampling01:20

Downsampling

131
When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
131

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Field strength-dependent sensitivity of chemical exchange saturation transfer: a methodological comparison of 3 Tesla and 7 Tesla in a clinical cohort.

Brain communications·2026
Same author

T1-weighting in Steady-State FLASH MRI-Diffusion Is Not Only Supportive but Mandatory for the Contrast.

Magnetic resonance in medicine·2026
Same author

Multispectral 7 Tesla MRI as a potential predictor of dopamine transporter deficiency in Parkinson's disease.

Imaging neuroscience (Cambridge, Mass.)·2026
Same author

Enhancing Accessibility and Engagement in the MRI Community: Reflections on the 2025 ISMRM MiniHub in Lille, France.

Magnetic resonance in medicine·2026
Same author

Multi-contrast generation and quantitative MRI using a transformer-based framework with RF excitation embeddings.

Communications biology·2025
Same author

Dynamic Transitions for Fast Joint Acquisition and Reconstruction of CEST- <math><semantics><mrow><msub><mrow><mi>R</mi></mrow> <mrow><mi>e</mi> <mi>x</mi></mrow></msub></mrow> <annotation>$$ {R}_{ex} $$</annotation></semantics></math> and <math><semantics><mrow><msub><mrow><mi>T</mi></mrow> <mrow><mn>1</mn></mrow></msub></mrow> <annotation>$$ {T}_1 $$</annotation></semantics></math>.

Magnetic resonance in medicine·2025

Related Experiment Video

Updated: Jun 7, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.5K

MR-zero meets FLASH - controlling the transient signal decay in gradient- and RF-spoiled gradient echo sequences.

Simon Weinmüller1, Jonathan Endres1, Nam Dang1

  • 1Institute of Neuroradiology, Uniklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany.

Magnetic Resonance in Medicine
|November 18, 2024
PubMed
Summary

Optimizing radiofrequency (RF) flip angles and phases in Fast Low Angle Shot (FLASH) MRI sequences significantly improves signal decay and reduces image artifacts. This method enhances overall image quality and stability.

Keywords:
Bloch optimizationFLASHMPRAGERF spoilingextended phase graphsgradient spoilingphase distribution graphs

More Related Videos

Gradient Echo Quantum Memory in Warm Atomic Vapor
10:00

Gradient Echo Quantum Memory in Warm Atomic Vapor

Published on: November 11, 2013

12.8K
Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
05:07

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

Published on: September 6, 2024

279

Related Experiment Videos

Last Updated: Jun 7, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.5K
Gradient Echo Quantum Memory in Warm Atomic Vapor
10:00

Gradient Echo Quantum Memory in Warm Atomic Vapor

Published on: November 11, 2013

12.8K
Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
05:07

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

Published on: September 6, 2024

279

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Pulse Sequence Design
  • Image Artifact Reduction

Background:

  • Transient signal decay in Fast Low Angle Shot (FLASH) MRI complicates accurate image reconstruction.
  • This signal complexity can introduce artifacts in both magnitude and phase images, hindering diagnostic utility.

Purpose of the Study:

  • To demonstrate that optimizing individual RF flip angles and phases can achieve near-ideal signal behavior.
  • To mitigate artifacts arising from complex signal decay in FLASH MRI readouts.

Main Methods:

  • Utilized the MR-zero differentiable end-to-end optimization framework to refine RF pulse trains for FLASH sequences.
  • Focused on minimizing deviations from an ideal mono-exponential Look-Locker signal decay.
  • Optimized individual flip angles, RF phases, or both, comparing results with conventional methods using Pulseq simulations.

Main Results:

  • Successfully reproduced the intricate substructure of transient FLASH signal decay.
  • Joint optimization of flip angles and RF phases yielded the best results, outperforming conventional quadratic RF cyclings.
  • Achieved superior performance in matching target signals, phase stability, point spread function ideality, parameter robustness, and image quality.

Conclusions:

  • Individual optimization of flip angles and RF phases is a powerful technique to enhance transient signal decay in FLASH MRI.
  • This approach offers significant improvements in image quality and artifact reduction for FLASH MRI sequences.