Mimicking and Measuring Occlusal Erosive Tooth Wear with the "Rub&Roll" and Non-contact Profilometry
Published on: February 2, 2018
Surface Roughness on Cementoenamel Junction After Rubber-Dam Clamp Application.
Ezgi Erden Kayalidere1, Merve Sahin1, Bora Korkut2
1Department of Restorative Dentistry, Faculty of Dentistry, Istanbul Kent University, Istanbul, Türkiye.
Different rubber-dam clamp types and application durations affect cementoenamel junction surface roughness. Metal clamps caused more damage than plastic ones, with prolonged application increasing defects.
Area of Science:
- Dental Materials Science
- Biomaterials Engineering
- Conservative Dentistry
Background:
- Rubber dam isolation is crucial in restorative dentistry.
- Retraction clamps are used to secure the rubber dam, but their impact on tooth structure is not fully understood.
- Surface integrity of the cementoenamel junction is vital for long-term tooth health.
Purpose of the Study:
- To evaluate the effect of different rubber-dam clamp types and application durations on cementoenamel junction (CEJ) surface roughness.
- To compare the surface morphology changes induced by polymer and metal clamps.
- To determine if application duration influences the degree of surface alteration.
Main Methods:
- Fifty-four extracted human molars were subjected to three types of rubber-dam clamps (polymer, flat-edge metal, serrated-edge metal) applied for 30 minutes, 1 hour, and 2 hours.
- Surface roughness was measured using a profilometer before and after clamp application.
- Scanning Electron Microscopy (SEM) was used to assess surface morphology changes.
- Statistical analysis included one-way ANOVA and Kruskal-Wallis tests.
Main Results:
- Significant increases in surface roughness were observed for all clamp types after 1 and 2 hours of application.
- The serrated-edge metal clamp showed a significant increase in roughness even after 30 minutes.
- SEM analysis revealed progressive microstructure defects, including cracks with metal clamps, as application time increased.
- The polymer clamp exhibited less surface alteration compared to metal clamps, especially at 1-hour application.
Conclusions:
- Rubber-dam clamp application can cause damage to the CEJ, with the extent of damage being dependent on the clamp type.
- Metal clamps, particularly those with serrated edges, pose a higher risk of surface damage compared to polymer clamps.
- While increased application duration generally leads to more surface alterations, the clamp type is a more significant factor in determining the severity of damage.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:37Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Porosity in Cement Paste
The balance of water to cement in the mix is...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Fineness of Cement
Direct...
Soundness of Cement