Related Experiment Video
Updated: Jun 7, 2025

Machine Learning Algorithms for Early Detection of Bone Metastases in an Experimental Rat Model
Published on: August 16, 2020
Deep Learning Algorithms for Breast Cancer Detection in a UK Screening Cohort: As Stand-alone Readers and Combined
Sarah E Hickman1, Nicholas R Payne1, Richard T Black1
1From the Department of Radiology, University of Cambridge School of Clinical Medicine, Box 218, Level 5, Cambridge Biomedical Campus, Cambridge CB2 0QQ, United Kingdom (S.E.H., N.R.P., Y.H., A.N.P., M.N., F.J.G.); Department of Radiology, Royal London Hospital, Barts Health NHS Trust, London, United Kingdom (S.E.H.); Department of Radiology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom (R.T.B., A.N.P., F.J.G.); Engineering and Physical Sciences Research Council Cambridge Mathematics of Information in Healthcare Hub, University of Cambridge, Cambridge, United Kingdom (Y.H.); Peel and Schriek Consulting, London, United Kingdom (S.H.); Department of Radiology, Norfolk and Norwich University Hospital, Norwich, United Kingdom (B.K., A.J.); and University of East Anglia, Norwich, United Kingdom (B.K.).
None:
Background Deep learning (DL) algorithms have shown promising results in mammographic screening either compared to a single reader or, when deployed in conjunction with a human reader, compared with double reading. Purpose To externally validate the performance of three DL algorithms as mammographic screen readers in an independent UK data set. Materials and Methods Three commercial DL algorithms (DL-1, DL-2, and DL-3) were retrospectively investigated from January 2022 to June 2022 using consecutive full-field digital mammograms collected at two UK sites during 1 year (2017). Normal cases with 3-year follow-up and histopathologically proven cancer cases detected either at screening (that round or next) or within the 3-year interval were included. A preset specificity threshold equivalent to a single reader was applied. Performance was evaluated for stand-alone DL reading compared with single human reading, and for DL reading combined with human reading compared with double reading, using sensitivity and specificity as the primary metrics. P < .025 was considered to indicate statistical significance for noninferiority testing. Results A total of 26 722 cases (median patient age, 59.0 years [IQR, 54.0-63.0 years]) with mammograms acquired using machines from two vendors were included. Cases included 332 screen-detected, 174 interval, and 254 next-round cancers. Two of three stand-alone DL algorithms achieved noninferior sensitivity (DL-1: 64.8%, P < .001; DL-2: 56.7%, P = .03; DL-3: 58.9%, P < .001) compared with the single first reader (62.8%), and specificity was noninferior for DL-1 (92.8%; P < .001) and DL-2 (96.8%; P < .001) and superior for DL-3 (97.9%; P < .001) compared with the single first reader (96.5%). Combining the DL algorithms with human readers achieved noninferior sensitivity (67.0%, 65.6%, and 65.4% for DL-1, DL-2, and DL-3, respectively; P < .001 for all) compared with double reading (67.4%), and superior specificity (97.4%, 97.6%, and 97.6%; P < .001 for all) compared with double reading (97.1%). Conclusion Use of stand-alone DL algorithms in combination with a human reader could maintain screening accuracy while reducing workload. Published under a CC BY 4.0 license. Supplemental material is available for this article.
More Related Videos
04:23A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
04:09Predicting Treatment Response to Image-Guided Therapies Using Machine Learning: An Example for Trans-Arterial Treatment of Hepatocellular Carcinoma
Published on: October 10, 2018