Order-disorder behavior in the ferroelectric nematic phase investigated via Raman spectroscopy
Thomas Raistrick1, Richard J Mandle1,2, Zhaopeng Zhang1
1School of Physics and Astronomy, <a href="https://ror.org/024mrxd33">University of Leeds</a>, Leeds LS2 9JT, United Kingdom.
Abstract:
Polar-ordered fluids are of interest both fundamentally and from an application standpoint. The recently discovered ferroelectric nematic phase is an example of a polar-ordered fluid, and while there has been extensive research interest in these materials, some of the fundamental properties are yet to be fully understood. Here, we report the order parameters of one of the first known materials that exhibit a ferroelectric nematic phase, RM734, determined via Raman spectroscopy. Raman spectroscopy been used extensively to determined order parameters in liquid crystals systems but also to probe ferroelectric behavior in solid ferroelectric systems and is therefore a powerful technique to study the ferroelectric nematic phase. A reduction and subsequent recovery of order parameters (Δ〈P_{2}〉≈0.1, Δ〈P_{4}〉≈0.06) is observed near the onset of the N to N_{F} transition, a feature that is confirmed via complementary birefringence measurements. This dip in order parameters has been attributed to splay fluctuations, which occur at the onset of the N_{F} transition; here we suggest a different explanation. A broadening of the full-width half-maxima (FWHM), of the order of 1 cm^{-1}, of the selected Raman peak is observed near the N to N_{F} phase transition, which we relate to either a change in reorientational dynamics or the onset of polar order. The N_{F} transition is analyzed using standard solid ferroelectric frameworks. An energetic barrier associated with the para- to ferroelectric transition is found to be of the order of 2.5±0.6kJ/mol, which is comparable to solid ferroelectric materials.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...