Related Experiment Video
Updated: Jun 7, 2025

Author Spotlight: Assessing the Feasibility of Using Amplitude-Integrated EEG During Neonatal Transport
Published on: June 21, 2024
The best indices of anaesthesia depth monitored by electroencephalogram in different age groups
Feixiang Li1, Bingqing Gong1, Huaichen Sheng2
1Department of Anesthesiology, Tianjin Medical University General Hospital, Tianjin Institute of Anesthesiology, Tianjin, China.
Abstract:
Introduction: Current electroencephalogram (EEG) indices for monitoring the depth of anaesthesia have not been adjusted for age. This study aims to identify the most suitable EEG indices for monitoring anaesthesia depth across different age groups.
Abstract:
Method: In here, we conducted a prospective observational trial to observe whether different EEG features in different age groups can detect anaesthesia depth and compare their performance.
Abstract:
Results: In Group 1, absolute θ had the highest prediction probability (Pk) value (0.78 ± 0.07), while relative γ had the lowest relative coefficient of variation (CV) value in states 1 (0.160), 2 (0.153), 3 (0.214) and 4 (0.144). In Group 2, absolute θ had the highest Pk value (0.81 ± 0.09), and relative γ had the lowest CV value in states 1 (0.159), 2 (0.178), 3 (0.140) and 4 (0.095). In Group 3, absolute δ had the highest Pk value (0.79 ± 0.08), with absolute slow wave having the lowest CV value in States 1 (0.196), 2 (0.258), 3 (0.295) and 4 (0.181). In Group 4, absolute δ had the highest Pk value (0.75 ± 0.10), and absolute slow wave had the lowest CV value in States 1 (0.176), 2 (0.192), 3 (0.185) and 4 (0.144).
Abstract:
Conclusion: In this study, we found that absolute θ and relative γ are the most suitable choices for young and middle-aged patients, while absolute δ and absolute slow wave are the most suitable choices for young elderly and elderly patients.
More Related Videos
05:58Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
Published on: September 6, 2017
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018