Related Experiment Video
Updated: Jun 7, 2025

Fast and Accurate Exhaled Breath Ammonia Measurement
Published on: June 11, 2014
Blood ammonia concentration measurement - effects of sampling site and cirrhosis during induced hyperammonaemia
Lars Djernes1,2,3, Hendrik Vilstrup1,4, Peter Ott1,4
1Department of Hepatology and Gastroenterology, Aarhus University Hospital, Aarhus, Denmark.
Background:
Ammonia is implicated in hepatic encephalopathy (HE) and prognostic in cirrhosis. Venous ammonia concentration, yielding similar correlation with HE grades as arterial, has become the preferred practise but comparative data are limited.
Aim:
To quantify effect of sampling site on ammonia concentration in healthy persons and patients with cirrhosis.
Methods:
Ammonia concentrations were measured by arterial and femoral venous blood sampling in ten healthy men and ten male patients with cirrhosis before and during hyperammonaemia induced by ammonia infusion. Cubital vein samples were included during the infusion.
Results:
At baseline, arterial-venous concentration gaps were similar (p = 0.15) in healthy persons [14 (10-19) and 8 (4-12) µmol/L] and patients with cirrhosis [53 (32-74) and 40 (23-57) µmol/L]. Ammonia infusion increased arterial-venous concentration gaps in both groups [115 (97-133) and 61 (31-90) vs. 175 (123-227) and 134 (65-203) µmol/L]. Mean ammonia concentration difference between groups during hyperammonaemia was 72 (42-103) µmol/L (p < 0.001) and independent of sampling site. Cubital and femoral vein concentrations were comparable (p = 0.26). In cirrhosis, calculated upper limit normal values (ULN) were comparable for arterial and venous blood at baseline [2.0 (1.2-2.8) and 2.1 (1.2-3.0), p = 0.74] and during hyperammonaemia [6.7 (4.7-8.7) and 6.2 (4.4- 8.1), p = 0.44].
Conclusions:
We found clinically meaningful intra-individual arterial-venous concentration gaps in both healthy persons and patients with cirrhosis at any ammonia concentration. Inter-group concentration differences after induced hyperammonaemia were relatively constant across sampling sites which supports clinical use of venous sampling. ULN-normalised ammonia concentrations were valid for both arterial and venous sampling.
More Related Videos
Related Concept Videos
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
NMR Spectroscopy Of Amines

