Related Experiment Video
Updated: Jun 7, 2025

Improved Renal Denervation Mitigated Hypertension Induced by Angiotensin II Infusion
Published on: May 26, 2022
Catheter-Based Renal Denervation for Resistant Arterial Hypertension: 10-Year Real-World Follow-Up Data
Sofie Brouwers1,2, Giulia Botti1,3, Matthias Verbesselt1,4
1Department of Cardiology, Cardiovascular Center Aalst, Aalst, Belgium.
Abstract:
This analysis of real-world data examines the efficacy, safety, and long-term outcomes of renal denervation in hypertensive patients for up to 10 years. Sixty-five consecutive patients underwent renal denervation (RDN) (single operator) for uncontrolled resistant hypertension. Efficacy was defined as the interindividual change of office (OBPM) and ambulatory blood pressure monitoring (ABPM) at 1, 6, 12 months, 2-4 and 5-10 years after RDN. Medication changes, renal function, and device generation disparities were analyzed. Of these patients, 42 received RDN with a first-generation device, while 23 underwent the procedure with a second-generation device. Baseline demographics included a predominantly male cohort (57.6%) with an average age of 60.3 years. The mean number of medications at baseline was 4.3. OBPM at baseline was 169.0/87.4 mmHg, and ABPM at baseline was 153.4/88.4 mmHg. Post-procedure, significant reductions in systolic blood pressure (SBP) were observed in both OBPM and ABPM at 1 month (OBPM 147.9/82.8 mmHg; ABPM 141.3/83.0 mmHg [SBP, p < 0.001]), sustained up to 10 years (OBPM 153.1/84.3 mmHg; ABPM 138/80.1 mmHg [SBP, p < 0.001]). After 1 year around half of patients had a controlled OBPM and 24 h ABPM < 135/85 mmHg, which was associated with a higher number of ablation spots (31.5±14.8 vs. 15.5 ± 6.5, p = 0.002) and occurred more often when treated with a second-generation device (2 [12.5%] vs. 7 [77.8%], p = 0.002). Renal function displayed a minor physiological decline over 5-10 years. No major complication occurred. Renal denervation demonstrated sustained significant reductions in systolic OBPM and ABPM up to 10 years post-procedure. Controlled blood pressure at 1 year was associated with a higher number of mean ablated spots and the use of a second-generation device. The procedure exhibited a favorable safety profile, indicating its viability in managing hypertension without significant renal function compromise.
More Related Videos
08:21A Modified Two Kidney One Clip Mouse Model of Renin Regulation in Renal Artery Stenosis
Published on: October 26, 2020
11:08Novel Approach for Simultaneous Recording of Renal Sympathetic Nerve Activity and Blood Pressure with Intravenous Infusion in Conscious, Unrestrained Mice.
Published on: February 14, 2018
Related Concept Videos
Heart Failure Drugs: Inhibitors of Renin-Angiotensin System
Antihypertensive Drugs: Direct Renin Inhibitors
Antihypertensive Drugs: Angiotensin II Receptor Blockers
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme...