Related Experiment Video
Updated: Jun 7, 2025

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
The Effect of Isometric Handgrip Training With and Without Blood Flow Restriction on Changes in Resting Blood
Robert W Spitz1, Vickie Wong2, Yujiro Yamada3
1University of Mississippi Medical Center.
Abstract:
To investigate the effects of high-intensity contractions and low-intensity contractions with and without blood flow restriction on changes in blood pressure and hemodynamic parameters. A total of 179 participants (18-35 years) were randomly assigned to one of three training groups that exercised 3 times per week for six weeks or a non-exercise control group. The groups are as follows: 1) Control [CON, n = 44]; 2) completed 4 sets of two-minute isometric contractions at 30% maximal voluntary contraction [LI, n = 47]; 3) completed 4 sets of two-minute isometric contractions at 30% maximal voluntary contraction with a 12 cm cuff inflated to 50% of arterial occlusion pressure [LI+BFR, n = 41]; or 4) completed 4 maximal isometric contractions lasting 5 seconds [MAX, n = 47]. Blood pressure, vascular resistance, and reactive hyperemia were measured at pre and post. Data are presented as means (SD). There was no evidence that SBP (BF10: 0.066), DBP (BF10: 0.057), vascular resistance (BF10: 0.085), or peak reactive hyperemia changed (BF10: 0.044) or A.U.C. (BF10: 0.074). Change scores for SBP were 1.1 (6.7), 0.7 (5.8), -0.4 (6.5), and -0.9 (6.3) mmHg for CON, LI, LI+BFR, and MAX, respectively. DBP change scores were 1.5 (6.6), 1.5 (7), -0.7 (5.9), and 0.3 (6.3) mmHg for CON, LI, LI+BFR, and MAX, respectively. Although recommended as a non-pharmacological method of blood pressure control, isometric exercise with or without BFR did not lower blood pressure. Future work could examine the inclusion of a daily strength test prior to the low intensity protocol.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...