Characterization of polyolefins-based pyrolysis oils: A comparison between one-dimensional gas chromatography and
Barbara Alejandra Perez1, J V Jayarama Krishna2, Hilal Ezgi Toraman3
1Department of Chemical Engineering, Pennsylvania State University, University Park, PA, 16801, USA.
Abstract:
The characterization of pyrolysis products is essential for the development of precise and accurate kinetic models. The resolution of pyrolysis products analyzed using traditional analytical methods may be compromised, resulting in inaccurate product identification and overlapped peaks. This study investigated the product distribution of pyrolysis oil derived from plastics using two analytical techniques: one-dimensional gas chromatography coupled with mass spectrometry (GC-MS) and two-dimensional gas chromatography coupled with flame ionization detector and time-of-flight mass spectrometer (GC×GC-FID/TOF-MS). Pyrolysis experiments of polypropylene (PP), high-density polyethylene (HDPE), polystyrene (PS), as well as co-pyrolysis of PP-PS and HDPE-PS, were conducted at 500 °C using a micropyrolyzer coupled with GC and GC×GC. GC×GC enabled the peak identification 2.8, 5.3, 4.8, 3, and 4.1 times more compared to GC in the pyrolysis of PP, HDPE, PS, PP-PS, and HDPE-PS, respectively. The yield of new chemical classes was found to be 1.3, 5.6, 0.2, 0.8, and 1.5 wt.% for pyrolysis of PP, HDPE, PS, PP-PS, and HDPE-PS, respectively. Furthermore, new products were detected in the co-pyrolysis of PP-PS (1:1), with a total yield of 0.5 ± 0.07 wt.%. Additionally, interaction effects were observed in the co-pyrolysis experiments, such as a 29.7% and 51.3 % increase in the experimental yield of toluene compared to the additive yield for PP-PS and HDPE-PS co-pyrolysis, respectively, which can be attributed to secondary reactions involving the consumption of styrene.
More Related Videos
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...