Fractionation and tidal characteristics of per- and polyfluoroalkyl substances in the estuarine maximum turbidity zone
Related Experiment Video
Updated: May 2, 2026

An Ultra-clean Multilayer Apparatus for Collecting Size Fractionated Marine Plankton and Suspended Particles
Published on: April 19, 2018
Chang Liu1, Xin-Xin Ma1, Si-Quan Wang2
1State Key Laboratory of Marine Environmental Science, Xiamen University, No.4221, Xiang'an South Road, Xiang'an District, Xiamen 361102, Fujian, China; College of the Environment and Ecology, Xiamen University, No.4221, Xiang'an South Road, Xiang'an District, Xiamen 361102, Fujian, China.
Abstract:
Complex tidal processes and suspended particulate matter (SPM) behavior influence the land-sea transport of terrestrial contaminants in estuaries. Contaminants are generally trapped within the estuarine maximum turbidity zone (MTZ), where SPM concentrations peak, misleading flux estimation. Here, we conducted high-resolution continuous sampling over two tidal cycles within the MTZ of a semidiurnal estuary. Tidal variations of per- and polyfluoroalkyl substances (PFAS), a class of persistent organic pollutants, were analyzed in dissolved water and size-fractionated SPM. Results showed that variations in dissolved PFAS may related to the mixing of upstream and downstream. The predominant size range for SPM was found in 1-31 μm (75 %, mainly 10-31 μm), but the PFAS tended to be sorbed by 0.22-1 μm (60 %) and > 31 μm (37 %) fractions. Except during periods of sediment resuspension when particulate PFAS concentration decreased, the PFAS concentration in the 1-31 μm increased during flood tides and decreased during ebb tides, which may not be related to organic carbon/elemental carbon levels. The hourly dynamic flux of dissolved-phase and particulate-phase PFAS transport to the sea in the MTZ was calculated by combining it with a hydrodynamic model. This study first highlights the size-fractionated PFAS transport under tidal influences and provides hourly flux estimation with a hydrodynamic model.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:06Investigating Long-Distance Transport of Perfluoroalkyl Acids in Wheat via a Split-Root Exposure Technique
Published on: September 28, 2022
Related Concept Videos
Centrifugation
Precipitation and Co-precipitation
Analyte Adsorption and Distribution
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...