Effects of Physiological-Scale Variation in Cations, pH, and Temperature on the Calibration of Electrochemical Aptamer-Based Sensors
Related Experiment Video
Updated: Jun 7, 2025

Phthalic Acid Ester-Binding DNA Aptamer Selection, Characterization, and Application to an Electrochemical Aptasensor
Published on: March 21, 2018
Lisa C Fetter1, Matthew H McDonough2,3, Tod E Kippin1,3,4
1Interdepartmental Program in Biomolecular Science and Engineering, University of California Santa Barbara, Santa Barbara, California 93106, United States.
Abstract:
Electrochemical aptamer-based (EAB) sensors are the first technology supporting high-frequency, real-time, in vivo molecular measurements that is independent of the chemical reactivity of its targets, rendering it easily generalizable. As is true for all biosensors, however, EAB sensor performance is affected by the measurement environment, potentially reducing accuracy when this environment deviates from the conditions under which the sensor was calibrated. Here, we address this question by measuring the extent to which physiological-scale environmental fluctuations reduce the accuracy of a representative set of EAB sensors and explore the means of correcting these effects. To do so, we first calibrated sensors against vancomycin, phenylalanine, and tryptophan under conditions that match the average ionic strength, cation composition, pH, and temperature of healthy human plasma. We then assessed their accuracy in samples for which the ionic composition, pH, and temperature were at the lower and upper ends of their physiological ranges. Doing so, we find that physiologically relevant fluctuations in ionic strength, cation composition, and pH do not significantly harm EAB sensor accuracy. Specifically, all 3 of our test-bed sensors achieve clinically significant mean relative accuracy (i.e., better than 20%) over the clinically or physiologically relevant concentration ranges of their target molecules. In contrast, physiologically plausible variations away from the temperature used for calibration induce more substantial errors. With knowledge of the temperature in hand, however, these errors are easily ameliorated. It thus appears that physiologically induced changes in the sensing environment are likely not a major impediment to clinical application of this in vivo molecular monitoring technology.
More Related Videos
13:15Fabrication of Electrochemical-DNA Biosensors for the Reagentless Detection of Nucleic Acids, Proteins and Small Molecules
Published on: June 1, 2011
08:23Design and Development of Aptamer–Gold Nanoparticle Based Colorimetric Assays for In-the-field Applications
Published on: June 23, 2016
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes
EDTA: Auxiliary Complexing Reagents
Determining the pH of Salt Solutions
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...