Objective:
To assess a comparative analysis of the ROX index, Wood-Downes-Ferrés score (WDF), p-ROXI, and the SpO2/FiO2 ratio as predictors of high-flow nasal cannula (HFNC) failure in children hospitalized for bronchiolitis.
Methods:
Data were extracted from the clinical trial "Comparison between HFNC and NIV in children with acute respiratory failure caused by bronchiolitis" conducted at a tertiary Brazilian hospital (Emergency Department and PICU). The inclusion criteria were children under 2 years of age admitted for bronchiolitis who developed mild to moderate respiratory distress and were eligible for HFNC therapy. Performance was determined by ROC and AUC metrics to define the best sensitivity and specificity for each variable. Children were evaluated at 0 h, 2 h, 6 h, 12 h, 24 h, 48 h, 72 h and 96 h after HFNC therapy initiation.
Results:
A total of 126 patients were recruited for this analysis. The median age was 3 months. Ninety-one percent of the patients had an identified viral agent, with RSV being the most common (65%). Twenty-three percent (29/126) of patients experienced failed HFNC therapy and required mechanical ventilation. The best cutoff points at 12 hours were 4.5 for WDF (AUC = 0.83, 0.74-0.92), 8.8 for ROX (AUC = 0.7, 0.54-0.84), 1.45 for p-ROXI (AUC = 0.56, 0.38-0-74), and 269 for SpO2/FiO2 (AUC = 0.64, 0.48-0.74). The scores and indices were also correlated with the PICU and hospital LOS.
Conclusions:
The ROX index and WDF were the most accurate scores for assessing HFNC failure considering 12-hour cutoff points.
Trial Registration Number:
U1111-1262-1740; RBR-104z966s. Date of registration: 03/01/2023.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...