Related Experiment Video
Updated: Jun 6, 2025

Assessment of Bone Fracture Healing Using Micro-Computed Tomography
Published on: December 9, 2022
Assessing bone quality in hounsfield units using computed tomography: what value should be used to classify bone as
Emily C Courtois1, Donna D Ohnmeiss2
1Texas Back Institute, Plano, Texas, USA.
Purpose:
The purpose of this study was to investigate threshold values for classifying bone as normal or osteoporotic based on Computed Tomography (CT) Hounsfield Units (HU) and to determine if clinically applicable values could be derived to aid spine surgeons evaluating bone quality using CT.
Methods:
This literature review was completed using PubMed and Ovid (MedLine), using syntax specific to bone quality and CT. The included articles were original clinical studies assessing bone quality and utilized composite L1-L4 HU values compared against dual-energy X-ray absorptiometry (DEXA) values. Extracted data study descriptors, CT measurement technique, and CT threshold values. CTs were measured from L1-L4 using either axial or sagittal images, and must classify their bone quality findings for any of the following 3 categories: normal, osteopenia, or osteoporosis.
Results:
This review located 34 studies measuring bone density using CT with threshold values, of which, 10 were included in the final review. Number of patients ranged from 74 to 283 and cohort ages from 20s to 70.6 years. CT threshold values for assessing normal and osteoporotic bone quality ranged from 150 to 179 and 87 to 155, respectively. From combining values across studies, a HU value of ≥ 170 HU was associated with normal bone and ≤ 115 HU with osteoporosis.
Conclusion:
There is variation in HU values used to differentiate normal from compromised bone quality, even after limiting studies. For patients with HU values between or near 170 or 115 HU, a DEXA scan may be warranted for further evaluation. With ongoing investigation in this area, threshold values for classifying bone quality using CT will be continually refined.
More Related Videos
09:02Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
06:59Author Spotlight: An Economic and Efficient Method for Quantitative Evaluation of Bone Microarchitecture in a Murine Osteoporosis Model
Published on: September 8, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
X-ray Imaging
Osteoclasts in Bone Remodeling
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...