Related Experiment Video
Updated: Jun 6, 2025

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
One-Year Comparison of Efficacy and Safety of PreserFlo MicroShunt with Mitomycin C Applied by Sub-Tenon Injection
Nora Majtanova1, Adriana Takacova2, Veronika Kurilova2
1Department of Ophthalmology, Slovak Medical University and University Hospital in Bratislava, Antolska 11, 851 07, Bratislava, Slovakia. nora.majtanova@gmail.com.
Introduction:
This study was performed to compare the efficacy and safety of PreserFlo MicroShunt (PMS) implantation with mitomycin C (MMC) applied by sub-tenon injection versus conventional application by MMC-soaked sponges.
Methods:
This retrospective, 1-year cohort study included 100 eyes of 100 patients with glaucoma who underwent PMS implantation with MMC (0.4 mg/ml) delivered either by sub-tenon injection (50 eyes) or via soaked sponges (50 eyes). The primary outcome measure at 1 year was intraocular pressure (IOP) reduction, with complete success defined as an IOP reduction of ≥ 20% and achieving a target IOP of ≤ 21 or 18 mmHg without the use of medication. Secondary outcomes, including corneal endothelial cell density (CECD) loss, the number of medications, and complications, were assessed and compared between the groups.
Results:
Sustained reductions in mean IOP were observed in both groups over the 1-year follow-up, with no significant differences between the groups. The complete success rate, with a target IOP of ≤ 21 mmHg after 1 year, was 19.3% in the sponge group and 26.4% in the injection group. The qualified success rate was 59.0% and 87.4% in the sponge and injection groups, respectively. A longer survival rate was observed in the injection group than in the sponge group when IOP was below 21 mmHg. The mean CECD significantly decreased (P < 0.01) from baseline to each postoperative follow-up time point in both groups. At 1 year postoperatively, the percentage of total CECD loss was 8.1% in the sponge group and 8.0% in the injection group. However, no significant differences in mean CECD values, the number of medications, or adverse events were found between the groups.
Conclusions:
PMS implantation with sub-tenon injection of MMC was comparable in terms of efficacy and safety to traditional MMC delivery via soaked sponges. However, the injection group demonstrated a significantly higher success rate than the sponge group.