Related Experiment Video
Updated: Aug 18, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
Peak hip external rotation torque and single-rater reliability is influenced by measurement position in the
Christina Frese1, Tobias Siebert2, Dieter Bubeck1
1Biomechanics and Sports Biology, University of Stuttgart, Stuttgart, Germany.
Abstract:
Measurement of hip external rotation strength (ERS) is important for preventive and rehabilitative purposes. ERS can be measured in 3 different positions in the isokinetic dynamometer ISOMED2000. However, it is not clear whether these measurement positions effect ERS nor if these positions are reliable in the ISOMED2000. Hence, the purpose of this study was to compare ERS in these positions, the reliability and the agreement. A cross-sectional design was conducted to compare measurement positions and a test-retest design to assess intra-rater reliability and agreement. Twenty-four healthy, physically active athletes participated in the study. Peak isometric torque was measured in the ISOMED in prone, supine, and side-lying position across two sessions on one day. Differences between positions were evaluated with the Wilcoxon-signed-rank test and cliff's delta. Reliability was assessed via intraclass correlation. Agreement was determined using the standard error of measurement (SEM), minimal detectable change (MDC), and Bland-Altman analysis (BAA). Results indicated a significant influence of measurement position on ERS (p < 0.001) with high effect sizes (>0.74). Reliability and agreement were high in all positions, but highest for the side-lying position (ICC = 0.90 [0.78, 0.96]; SEM = 0.08; MDC = 0.23; BAA_bias = 3.4 %, BAA_loA = 37 %). There were only poor to moderate correlations between measurement positions. These findings suggest that measurement position significantly affects ERS. Furthermore, the effect varies across individuals indicating that normative values cannot be used interchangeably or be adapted across positions. In diagnostic testing ERS should be measured in the same position, but preferably in the side-lying position.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
Related Concept Videos
Angle of Twist - Elastic Range
Measurements of Strain
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Common Leveling Mistakes and Errors