Diffuse transmittance spectroscopy for ultra short-term measurement of pulse rate variability in healthy subjects
1Institute of Metrology and Biomedical Engineering, Faculty of Mechatronics, Warsaw University of Technology, Św. A. Boboli 8 St., Warsaw 02-525, Poland.
Abstract:
Multi-wavelength plethysmography (MWPPG) is a growing technique for noninvasive hemodynamic measurements, particularly spectral based methods. Different wavelengths have been investigated for both transmissive and reflectance PPG configurations. The objective of this work is to investigate the feasibility of Diffuse Transmittance Spectroscopy (DTS) for Pulse Rate Variability (PRV) measurements and to evaluate the performance of diffuse transmittance spectroscopy in quantifying ultrashort pulse rate variability. DTS was used for reconstructing PPG signal followed by PRV analysis. DTS and reference PPG recordings were acquired from 18 healthy subjects in total. PRV features include time-domain, and frequency-domain features are extracted from 50 s duration. The extracted PRV parameters were compared to PRV parameters derived from conventional pulse oximetry-based PPG. Pulse rate variability analysis was applied on DTS and reference PPG tracings. The comparison demonstrated a strong correlation between the diffuse transmittance spectral method and the gold standard PPG sensor. Significant correlation (r > 0.90, p < 0.05) was found between PRV from DTS and reference PRV for mean intervals, standard deviation of intervals (SDNN) and the root-mean square of the difference of successive intervals (RMSSD). A good agreement was found between PRV Parameters in time domain of PPG analysis using Bland-Altman plots with 95 % limits of agreements. However, Bland-Altman analysis showed a considerable divergence in frequency parameters. The study also revealed that PPG based diffuse transmittance measurements were insensitive to ambient noise in comparison with conventional pulse oximeter. The results suggest a potential application of the diffuse transmittance spectroscopy for pulse rate variability analysis.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
06:50Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Related Concept Videos
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Regulation of Pulse
Pulse
The pulse serves as a clinical...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...