Investigating cross-section effects on HPGe detector response through computational and empirical approaches
Ghada Mellak1, Wassila Boukhenfouf1, Fatma Zohra Dehimi2
1Laboratory of Dosing, Analysis and Characterization with High Resolution, Department of Physics, Faculty of Science, Ferhat Abbas University, Setif, Algeria.
Abstract:
The combination of experimental measurements and simulations provides valuable insights into the performance and limitations of gamma-ray spectrometry, especially within a specified energy range. This study investigates the impact of cross-section variations on the response of high-purity germanium (HPGe) detectors, focusing on the energy range from 53 keV to 1408 keV. Monte Carlo simulations using the MCNP5 code with two different cross-section libraries, ENDF/B.VI and JENDL-5, are conducted alongside a semi-empirical method utilizing ANGLE 4.0 software. This approach allows for a comprehensive exploration of how cross-section variations affect HPGe detector response. The flexibility in library selection highlights the adaptability of MCNP to cater to specific energy requirements. The calculated efficiencies are then compared with experimental data to evaluate accuracy and reliability. The results reveal an agreement within [2-3%] between experimental and simulated values, particularly for energies above 121 keV. Notably, for low-energy ranges (53-121 keV), the ENDF/B.VI library achieves an accuracy within [3-5%], making it effective at capturing low-energy interactions and enhancing prediction precision. This accuracy highlights its suitability for capturing low-energy interactions and enhances prediction precision. Overall, this study provides valuable insights into detector performance and underscores the significance of library choice in ensuring simulation accuracy.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....