Prevent hypoglycaemia when using automated insulin delivery systems in type 1 diabetes requires near normal glycaemic
Louis Monnier1, Claude Colette1, Eric Renard2
1Medical School of Montpellier, University of Montpellier, avenue du doyen Giraud cedex 5, 34093 Montpellier, France.
Aim:
Although newer technologies of insulin delivery in type 1 diabetes have facilitated an improvement in glycaemic control the risk of hypoglycaemia remains a threat. Therefore, it is important to define the thresholds of glycaemic variability below which the risk of hypoglycaemia can be eliminated or at least minimized.
Methods:
Randomized controlled trials conducted from 2017 to 2023 comparing Sensor-Augmented-Pumps and Augmented Insulin Delivery Systems (n = 16 and 22 studies, respectively) were selected. A weighted linear model of regression was used to compute the relationship between glycaemic variability and times spent below glucose range. The intercepts of regression lines with the abscissa axis (time below range = 0 %) defined the glycaemic variability thresholds.
Results:
Positive relationships were observed between the 2 metrics. The scatter plots indicated that the times spent below range never reached the value of 0 % and that the glycaemic variability never fell below 28 %. By extrapolating the regression lines, the glycaemic variability at intercepts with time below range < 70 mg/dL of 0 % was 30.1 % with sensor augmented pumps and 18.9 % with automated insulin delivery. For a time below range < 54 mg/dL of 0 % the respective glycaemic variability values were 32.7 % and 19.9 % (with sensor augmented pumps and automated insulin delivery, respectively).
Conclusions:
Importantly, glycaemic variability targets and ambient hyperglycaemia are interdependent. Users of automated insulin delivery need to reach a glycaemic variability of 18 % to 20 % to minimize or eradicate the risk of hypoglycaemia. Such values are those observed in healthy non-diabetic people.
More Related Videos
08:32Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain
Published on: January 4, 2018
07:35Author Spotlight: Investigating the Blood Glucose Homeostasis in Murine Brain Using a Cost-Effective Hyperglycemic And Hypoglycemic Clamp Technique
Published on: January 26, 2024
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Hypoglycemia and Glucagon
Oral Hypoglycemic Agents: Glinides
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...