Challenges of Continuous Wave EPR of Broad Signals-The Ferritin Case
Fabio Seiji Otsuka1, Maria Concepción García Otaduy2, Otaciro Rangel Nascimento3
1InBrain Lab, Department of Physics, Faculty of Philosophy, Sciences and Letters of Ribeirão Preto (FFCLRP), University of São Paulo, Ribeirão Preto, Brazil.
Abstract:
The study of continuous wave (cw) electron paramagnetic resonance (EPR) spectra still poses a challenge for very broad signals, especially when the spectrum extends over a large part of the accessible field range. The difficulties derive from instrumental challenges, because of insufficient modulation depth and the need to apply measurement conditions that enhance cavity background. The biggest problem, however, is how to define a baseline such that spectral distortions are minimized. Conventional methods rely on a suitable choice of points outside the range of the signal of interest to perform a polynomial interpolation. These methods are effective in most cases where the signal of interest comprises only a narrow range of magnetic field (narrow features). In this study, a novel method of baseline correction for broad signals is proposed and compared to conventional methods. It takes into account that there are only few anchor points for the baseline. The method is applied to the signal of the iron-storage protein ferritin. The ferritin signal is a broad band that extends from zero to 0.8 T. An approach is developed by which this broad signal is analyzed reliably. The method is also extended to the case where the broad signal is superimposed on narrow signals and enables to extract the parameters of both types of signals in a fitting pipeline.
Supplementary Information:
The online version contains supplementary material available at 10.1007/s00723-024-01719-y.
More Related Videos
Related Concept Videos
NMR Spectrometers: Resolution and Error Correction
Electron Paramagnetic Resonance (EPR) Spectroscopy: Organic Radicals
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences