Related Experiment Video
Updated: Jun 6, 2025

Activated Cross-linked Agarose for the Rapid Development of Affinity Chromatography Resins - Antibody Capture as a Case Study
Published on: August 16, 2019
Comparison of Conjugates Obtained Using DMSO and DMF as Solvents in the Production of Polyclonal Antibodies and ELISA
Anna N Berlina1, Nadezhda S Komova1, Kseniya V Serebrennikova1
1A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia.
Abstract:
When developing immunochemical test systems, it is necessary to obtain specific antibodies. Their quality depends, among other things, on the immunogen used. When preparing hapten-protein conjugates to obtain antibodies for low-molecular-weight compounds, the key factors are the structure of the hapten itself, the presence of a spacer, the size of the carrier protein and the degree of its modification by hapten molecules. This work shows that one additional factor-the conditions for obtaining the hapten-protein conjugate-is overlooked. In this work, we have synthesized conjugates of bisphenol A derivative 4,4-bis(hydroxyphenyl)valeric acid (BVA), the protein carrier soybean trypsin inhibitor (STI), and bovine serum albumin (BSA) in reaction media combining water with two organic solvents: dimethylformamide (DMF) or dimethyl sulfoxide (DMSO). Namely, BSADMF-BVA, STIDMF-BVA, BSADMSO-BVA and STIDMSO-BVA conjugates were obtained. Rabbit polyclonal antibodies against the BSADMF-BVA conjugate demonstrated basically different interactions in the developed ELISA systems using either STIDMF-BVA or STIDMSO-BVA conjugates. The use of the STIDMF-BVA conjugate demonstrated the absence of competition in combination with antisera obtained from BSADMF-BVA in an ELISA. A competitive interaction was observed only with the use of the STIDMSO-BVA conjugate. Under the selected conditions, the detection limit of bisphenol A was 8.3 ng/mL, and the working range of determined concentrations was 18.5-290.3 ng/mL. The obtained data demonstrate the possibility of achieving sensitive immunoassays by simply varying the reaction media for the hapten-protein conjugation, which could provide an additional tool in the development of immunoassays for other low-molecular-weight compounds.
More Related Videos
10:35Chemical Conjugation of a Purified DEC-205-Directed Antibody with Full-Length Protein for Targeting Mouse Dendritic Cells In Vitro and In Vivo
Published on: February 5, 2021
10:17Creating Highly Specific Chemically Induced Protein Dimerization Systems by Stepwise Phage Selection of a Combinatorial Single-Domain Antibody Library
Published on: January 14, 2020