Evaluating the Usability of a Remote Ischemic Conditioning Device for Pre-Hospital Stroke Management: Insights from
Bogna Anna Drozdowska1, Kaden Lam1,2, Cody Doolan1
1Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB T2N 2T9, Canada.
Background/Objectives:
In acute stroke, often-prolonged hospital transport times present an opportunity for early interventions to salvage brain tissue. Remote ischemic conditioning (RIC), where brief cycles of ischemia-reperfusion in a limb are induced to protect the brain, is a promising treatment for this setting. We assessed the usability of a novel RIC system in a simulated emergency response scenario.
Methods:
Paramedics were asked to use the RIC device in an emergency stroke care and ambulance transport simulation, overseen by a confederate. Feedback on device use was collected through questionnaires, including the System Usability Scale (SUS) and the NASA Task Load Index (NASA-TLX), and a semi-structured interview. Questionnaire responses were summarized using descriptive statistics; interview transcripts were analyzed thematically.
Results:
Nine paramedics (including the confederate) participated, with a mean of 10.0 ± 10.3 years of professional experience. Questionnaire responses indicated high device usability (mean SUS score: 85.3 ± 12.9 out of 100) and low task-related demands, effort, and frustration (mean NASA-TLX domain scores: ≤3.9 out of 20). Seven paramedics stated they would use the device in daily practice. They expressed concerns related to display screen clarity, interference with standard procedures, cable management, device fragility, and patient discomfort. Suggested improvements included adding indicators of device performance and refining the cuff design.
Conclusions:
While the device was considered easy to use, paramedics also identified important areas of improvement. With a small, localized study sample, our findings are primarily applicable to the refinement of the RICovery system for use in future clinical trials in the same healthcare setting. However, feedback on the importance of mitigating potential interference of newly introduced procedures with those already established, robustness of equipment, and effective paramedic-patient communication may also help inform the design of other pre-hospital interventions.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...