A deep learning method for the recovery of standard-dose imaging quality from ultra-low-dose PET on wavelet domain
Song Xue1,2, Fanxuan Liu1, Hanzhong Wang3,4,5,6
1Department of Nuclear Medicine, Bern University Hospital, Inselspital, University of Bern, Bern, Switzerland.
Purpose:
Recent development in positron emission tomography (PET) dramatically increased the effective sensitivity by increasing the geometric coverage leading to total-body PET imaging. This encouraging breakthrough brings the hope of ultra-low dose PET imaging equivalent to transatlantic flight with the assistance of deep learning (DL)-based methods. However, conventional DL approaches face limitations in addressing the heterogeneous domain of PET imaging. This study aims to develop a wavelet-based DL method capable of restoring high-quality imaging from ultra-low-dose PET scans.
Materials And Methods:
In contrast to conventional DL techniques that denoise images in the spatial domain, we introduce WaveNet, a novel approach that inputs wavelet-decomposed frequency components of PET imaging to perform denoising in the frequency domain. A dataset comprising total-body 18F -FDG PET images of 1447, acquired using total-body PET scanners including Biograph Vision Quadra (Siemens Healthineers) and uEXPLORER (United Imaging) in Bern and Shanghai, was utilized for developing and testing the proposed method. The quality of enhanced images was assessed using a customized scoring system, which incorporated weighted global physical metrics and local indices.
Results:
Our proposed WaveNet consistently outperforms the baseline UNet model across all levels of dose reduction factors (DRF), with greater improvements observed as image quality decreases. Statistical analysis (p < 0.05) and visual inspection validated the superiority of WaveNet. Moreover, WaveNet demonstrated superior generalizability when applied to two cross-scanner datasets (p < 0.05).
Conclusion:
WaveNet developed with total-body PET scanners may offer a computational-friendly and robust approach to recover image quality from ultra-low-dose PET imaging. Its adoption may enhance the reliability and clinical acceptance of DL-based dose reduction techniques.
More Related Videos
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET