A real-world comparison of the diagnostic performances of six different TI-RADS guidelines, including
Osman Melih Topcuoglu1, Betul Uzunoglu1, Tolga Orhan1
1Yeditepe University Hospitals, Department of Radiology, Kosuyolu 34718, Istanbul, Turkey.
Insights
This study compared six thyroid nodule (TN) guidelines for diagnosing malignancy. The Chinese TIRADS (C-TIRADS) showed the highest accuracy and lowest miss rate, suggesting its superior performance in differentiating malignant from benign thyroid nodules.
Area of Science:
- Radiology
- Oncology
- Endocrinology
Background:
- Thyroid nodules (TN) are common, and accurate differentiation between benign and malignant types is crucial for appropriate patient management.
- Several Thyroid Imaging Reporting and Data System (TIRADS) guidelines exist, but their comparative diagnostic performance needs further evaluation.
Purpose of the Study:
- To compare the diagnostic performance of six current TIRADS guidelines in differentiating malignant from benign thyroid nodules (TN).
- The guidelines evaluated include American College of Radiology (ACR-TIRADS), Kwak-TIRADS, Korean (K-TIRADS), European (EU-TIRADS), American Thyroid Association (ATA), and Chinese (C-TIRADS).
Main Methods:
- Retrospective analysis of 829 pathologically proven thyroid nodules (234 malignant, 595 benign) between January 2007 and September 2023.
- Ultrasound images were categorized using the six different TIRADS guidelines.
- Diagnostic performance metrics, including Area Under Curve (AUC), sensitivity, specificity, positive and negative predictive values (PPV, NPV), and miss rates for malignancy (MRM), were calculated for each guideline.
Main Results:
- All six guidelines demonstrated effective differentiation of malignant from benign TNs with comparable diagnostic performances.
- Chinese TIRADS (C-TIRADS) exhibited the highest AUC (0.842) and the lowest miss rate for malignancy (0.1%).
- Specific performance varied, with C-TIRADS showing 92.8% specificity and 68.8% accuracy, while ACR-TIRADS had 99.8% sensitivity but only 27.1% specificity.
Conclusions:
- Six current TIRADS guidelines offer effective differentiation of malignant from benign thyroid nodules.
- C-TIRADS demonstrated superior performance in this study, evidenced by the highest AUC and lowest miss rate for malignancy.
- The findings suggest C-TIRADS may be a more optimal choice for thyroid nodule risk stratification.
Purpose:
To compare the diagnostic performance of six different currently available guidelines including the American College of Radiology Thyroid Imaging and Reporting Data System (ACR-TIRADS), Kwak-TIRADS, Korean TIRADS (K-TIRADS), European TIRADS (EU-TIRADS), American Thyroid Association (ATA) and Chinese TIRADS (C-TIRADS), in differentiating malignant from benign thyroid nodules (TN).
Materials And Methods:
In this single-center study, between January-2007 and September-2023, ultrasound (US) images of TNs that were pathologically proven either by surgery or by fine needle aspiration biopsy (FNAB), were retrospectively evaluated and categorized according to six different currently available guidelines. Area under curve (AUC), sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively) and miss rates for malignancy (MRM) were calculated for each guideline.
Results:
A total of 829 TNs (n = 234 malignant and n = 595 benign) were included. AUC, sensitivity, specificity, PPV, NPV and accuracy for ACR-TIRADS were 0.786, 99.8 %, 27.1 %, 31.92 %, 99.73 % and 54.6 %, respectively; for Kwak-TIRADS 0.839, 97.8 %, 42.1 %, 36.29 %, 98.11 % and 63.1 %, respectively; for K-TIRADS 0.797, 97.6 %, 41.6 %, 36.01 %, 84.85 % and 62.8, respectively, for EU-TIRADS 0.766, 97.8 %, 35.6 %, 33.89 %, 97.92 % and 59.1 %, respectively, for ATA 0.788, 97.5 %, 49.8 %, 32.86 %, 88.16 % and 64.2 %, respectively and for C-TIRADS 0.842, 0 %, 92.8 %, 54.3 %, 39.53 %, 90.42 %, and 68.8 % respectively. MRM regarding ACR-/Kwak-/K-/EU-/ATA-/C-TIRADS were 2.2 %, 0.5 %, 2.9 %, 2.5 %, 3.3 % and 0.1 %, respectively.
Conclusion:
Six different currently available TIRADS guidelines can provide effective differentiation of malignant TNs from benign ones with similar diagnostic performances. However; C-TIRADS offered the highest AUC and the lowest MRM than the other guidelines, in this series.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
10:26A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Receiver Operating Characteristic Plot
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT