A Proof-of-Principle Study for δ15N Measurements of Aqueous Dissolved Nitrate With a Modified LC-IRMS Interface
Tobias Hesse1,2, Felix Niemann1, Shaista Khaliq1
1Instrumental Analytical Chemistry, University of Duisburg-Essen, Essen, Germany.
Rationale:
The analysis of nitrogen isotopes in aqueous dissolved nitrate is an effective method for identifying pollution sources and offers the potential to study the nitrogen cycle. However, the measurement of nitrogen isotope ratios of nitrate still requires extensive sample preparation or derivatization.
Methods:
In this study, a modified commercially available liquid chromatography-isotope ratio mass spectrometer (LC-IRMS) interface is presented that enables automated measurement of δ15N signatures from nitrate by online reduction of nitrate in two consecutive steps. First, vanadium(III) chloride is used as a reducing agent to convert NO3 - to NxOy under acidic conditions. The mix of nitrogen oxides is then transferred into a stream of helium and reduced to nitrogen (N2) analysis gas via a hot copper reactor. Prior to the online conversion of aqueous nitrate into elemental nitrogen, the sample was chromatographically separated from potential matrix effects on a PGC column.
Results:
Precision was achieved at a level below 1.4‰ by injecting 10 μL of 50 mg L-1 N, using five different nitrate standards and reference materials. These materials spanned a range of more than 180‰ in δ15N. To demonstrate the applicability of the method, we measured water samples from an enrichment experiment, where isotopically enriched ammonium chloride was administered into a small river over the course of 2 weeks. In contrary to our expectation, the δ15N values of river nitrate showed values between +0.4 ± 0.4‰ and +4.1 ± 0.3‰, varying over a small range of 3.7‰.
Conclusions:
Our study showed that the measurement of nitrate nitrogen isotope ratios with a modified LC-IRMS system is possible but that further modifications and improvements would be necessary for a robust and user-friendly instrument.
More Related Videos
07:14Automated, High-resolution Mobile Collection System for the Nitrogen Isotopic Analysis of NOx
Published on: December 20, 2016
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
Related Concept Videos
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...