Related Experiment Videos
Management of acute postoperative intraocular pressure elevation by laser-induced filtration
Journal of Cataract and Refractive Surgery
|January 1, 1986
Abstract:
We describe a simple, rapid technique for creating a filtering bleb in the early postoperative period using the argon or Nd:YAG laser. After cutting a suture, an immediate reduction of the intraocular pressure will result as filtration occurs, thereby safely eliminating the need for and the risk of traditional surgery.