Application of Real-Time Palm Imaging with Nelder-Mead Particle Swarm Optimization/Regression Algorithms for
Te-Jen Su1, Ya-Chung Hung1, Wei-Hong Lin1
1Department of Electronic Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung 807618, Taiwan.
Abstract:
In response to the rising prevalence of hypertension due to lifestyle changes, this study introduces a novel approach for non-contact blood pressure (BP) monitoring. Recognizing the "silent killer" nature of hypertension, this research focuses on developing accessible, non-invasive BP measurement methods. This study compares two distinct non-contact BP measurement approaches: one combining the Nelder-Mead simplex method with particle swarm optimization (NM-PSO) and the other using machine learning regression analysis. In the NM-PSO method, a standard webcam captures continuous images of the palm, extracting physiological data through light wave reflection and employing independent component analysis (ICA) to remove noise artifacts. The NM-PSO achieves a verified root mean square error (RMSE) of 2.71 mmHg for systolic blood pressure (SBP) and 3.42 mmHg for diastolic blood pressure (DBP). Alternatively, the regression method derives BP values through machine learning-based regression formulas, resulting in an RMSE of 2.88 mmHg for SBP and 2.60 mmHg for DBP. Both methods enable fast, accurate, and convenient BP measurement within 10 s, suitable for home use. This study demonstrates a cost-effective solution for non-contact BP monitoring and highlights each method's advantages. The NM-PSO approach emphasizes optimization in noise handling, while the regression method leverages formulaic efficiency in BP estimation. These results offer a biomimetic approach that could replace traditional contact-based BP measurement devices, contributing to enhanced accessibility in hypertension management.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: