Related Experiment Video
Updated: May 11, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Modelling of coronary artery stenosis and study of hemodynamic under the influence of magnetic fields
Chandra Shekhar Maurya1, Abhijeet Kumar1
1Department of Mechanical Engineering, Indian Institute of Technology Bombay, Mumbai-400076, India.
Abstract:
Investigating magnetic blood flow characteristics through arteries and micron-size channels for clinical therapies in biomedicine is becoming increasingly important with the rise of point-of-care diagnostics devices. A computational fluid dynamics (CFD) investigation is conducted to explore blood flow within a coronary artery affected by an elliptical stenosis near the artery wall under the influence of a magnetic field. The novelty of our study is the integration of Navier-Stokes and Maxwell's equations to calculate body forces on fluid flow, coupled with the application of magnetic fields both longitudinally and vertically, and the use of the Carreau-Yasuda model to analyse non-Newtonian blood rheology. Blood flow is modelled by solving the incompressible continuity and momentum equations, considering laminar and non-Newtonian properties, with the finite element-based solver COMSOL Multiphysics. The CFD model is validated using previously published analytical and computational data. This study investigates the effects of magnetic fields on blood flow through stenotic arteries with 25 %, 35 %, and 50 % stenosis, examining how the magnetic field and its orientation impact variations in velocity profiles, pressure drop, and wall shear stress (WSS). Our results show that magnetic fields can effectively manipulate blood flow, causing acceleration or deceleration depending on field direction. Significant changes in hemodynamics are observed, particularly at 50 % arterial stenosis, highlighting the profound impact of stenosis on flow characteristics. Compared to healthy arteries, the velocity change in stenosed arteries increased by 16.5 %, 29.4 %, and 62.1 % for 25 %, 35 %, and 50 % stenosis, respectively. The findings advance experimental models of blood flow in magnetic fields, highlighting the critical importance of regulating blood velocity and pressure. These insights are particularly valuable for developing drug delivery systems and magnetic-driven blood pumps.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI