Related Experiment Video For breast cancer survivors
Updated: Jun 6, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Reproducibility of Thermography for Measuring Skin Temperature of Upper Limbs in Breast Cancer Survivors
Vanessa Maria da Silva Alves Gomes1, Naiany Tenório1, Ana Rafaela Cardozo da Silva1
1Departamento de Fisioterapia, Centro de Ciências da Saúde, Universidade Federal de Pernambuco, Recife 50670-901, Brazil.
Abstract:
Background/Objectives: Breast cancer-related lymphedema (BCRL) is a chronic condition that has early diagnosis as a critical component for proper treatment. Thermography, a non-invasive imaging method, is considered a promising complementary tool for the diagnosis and monitoring of BCRL, especially in subclinical stages. The present study aimed to evaluate the intra- and inter-examiner reproducibility of thermography for measuring the skin temperature of the upper limbs (UL) of women with and without BCRL. Methods: This study, conducted with women who underwent a unilateral mastectomy, assessed BCRL using indirect volumetry. Maximum, minimum, and mean skin temperatures were measured in five regions of interest (ROI) of each UL (C1, C2, C3, C4, and Cup) in four different postures. Reproducibility measures were assessed using an intraclass correlation coefficient, 95% confidence interval, and coefficient of variation. Results: The sample comprised 30 women; 14 were diagnosed with BCRL. A total of 120 thermograms were recorded in different postures, and 3600 ROI were analyzed in the UL with and without BRCL. The intraclass correlation coefficient of the analyses indicated intra- and inter-examiner reproducibility from good to excellent (0.82 to 1.00) for all skin temperatures evaluated (maximum, minimum, and mean). The coefficient of variation for all measures was below 10%, indicating low variability. Conclusions: Our findings demonstrate that thermography shows good-to-excellent reproducibility across multiple postures and regions of interest, reinforcing its potential as a non-invasive and reliable method for assessing lymphedema in breast cancer survivors. This study establishes a foundation for incorporating thermography into clinical practice for early BCRL detection, particularly in subclinical stages, thus improving patient management and outcomes.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...