Related Experiment Video
Updated: Jun 6, 2025

Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Investigating the Potential Overuse of Pan-Computed Tomography (PanCT) Examinations in Trauma Cases in Emergency
Haitham Alahmad1, Ahmed Hobani2, Mohammed Alasmi2
1Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, Riyadh 11451, Saudi Arabia.
Abstract:
Background and Objectives: The increasing use of whole-body computed tomography (WBCT) examinations, also known as panCT, in emergency departments for trauma patients has raised concerns about potential overuse and the associated risk of unnecessary radiation exposure. The purpose of this study was to examine the utilization patterns and findings of panCT scans performed over one year at a major academic hospital. Materials and Methods: This retrospective cohort study included 531 stable trauma adult patients who underwent panCT scans in 2023. De-identified data for each patient, including the radiology report, age, gender, and total dose-length product (DLP) of the panCT scan, were retrieved and reviewed. Radiology reports were classified based on the findings as negative (no acute traumatic injuries) or positive, with positive reports further subclassified based on injury location. Injury severity scores (ISS) were also calculated based on the findings of the radiology reports. Statistical analysis was performed using the Python programming language to assess any association between the independent variables (age and gender) and the dependent variable (report findings: negative or positive). Results: About 57% (n = 303) of the panCT scans included in the analysis were negative. The chi-squared test and logistic regression revealed a significant association between age and report finding (negative or positive), while no association with gender was found. One-third of positive cases (n = 72) had injuries only in the head and neck (H&N) region, and another one-third (n = 72) had injuries only in chest-abdomen-pelvis (CAP) region. Most cases (n = 373; 70%) had an ISS between 1 and 8, which is a mild score. Conclusions: This study showed a high rate of negative panCT scans, suggesting potential overuse of panCT. The study results highlight the need for more selective CT imaging approaches in emergency settings. Following evidence-based guidelines and decision-support tools could promote appropriate utilization of panCT scans, reducing unnecessary radiation exposure while ensuring that high-risk patients in emergency setting receive appropriate imaging.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...

