[Quantitative evaluation of pulsatile flow in the extremities using a rheographic method].

N M Krivitskiĭ

    Meditsinskaia Tekhnika
    |January 1, 1986
    PubMed
    Summary

    This study presents a model for measuring limb pulse blood flow using four-electrode impedance. It provides formulas and analysis to improve accuracy by considering factors like skin conditions and electrode placement.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    [The electrical impedance indicator dilution method in studying the basic hemodynamic parameters during dialysis].

    Urologiia i nefrologiia·1991
    Same author

    [Effects of volume and rate of blood loss on indicators of auto-hemodilution].

    Biulleten' eksperimental'noi biologii i meditsiny·1991
    Same author

    [The use of a vitamin and metabolite complex for correcting the disorders in systemic and organ hemodynamics during liver resection under conditions of acute blood loss].

    Patologicheskaia fiziologiia i eksperimental'naia terapiia·1990
    Same author

    [The evaluation of systemic and organ hemodynamics during liver resection under conditions of acute blood loss by means of electroimpedance indicator dilution].

    Patologicheskaia fiziologiia i eksperimental'naia terapiia·1990
    Same author

    [Possibilities of the method of dilution of electro-impedance indicators in the assessment of volume dynamics of extravascular lung fluid in intensive care and resuscitation units].

    Vestnik Akademii meditsinskikh nauk SSSR·1990
    Same author

    [Assessment of fluid balance and several hemodynamic parameters in lung surgery using the method of impedance plethysmography].

    Vestnik Akademii meditsinskikh nauk SSSR·1990

    Area of Science:

    • Biomedical Engineering
    • Electrical Impedance Tomography
    • Hemodynamics

    Context:

    • Assessing peripheral vascular health is crucial for diagnosing and managing various circulatory conditions.
    • Non-invasive methods for quantifying blood flow are essential for clinical practice and research.
    • Existing techniques for blood flow measurement may have limitations in accuracy or applicability to specific body parts.

    Purpose:

    • To develop a mathematical model for estimating limb pulse blood flow using electrical impedance measurements.
    • To derive exact and approximate expressions for impedance in a multilayer cylindrical model of a limb segment.
    • To analyze factors influencing measurement accuracy and provide recommendations for optimizing electrode placement.

    Summary:

    • A multilayer cylindrical model of a limb segment was used to measure impedance with four electrodes.
    • Exact and approximate impedance expressions were derived, enabling the calculation of pulse blood flow.
    • Factors affecting accuracy, including skin condition, vessel depth, and electrode positioning, were analyzed.

    Impact:

    • Provides a method for accurate, non-invasive assessment of limb pulse blood flow.
    • Offers guidance on optimizing electrode spacing for reliable measurements across different body parts.
    • Contributes to the advancement of non-invasive hemodynamic monitoring techniques.