Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
The Effects of Intensity, Exposure Time, and Distance of Polymerization Light on Vickers Microhardness and
Damir Duratbegović1, Nedim Pervan2, Selma Jakupović3
1Department of Pediatric and Preventive Dentistry, Faculty of Dentistry with Dental Clinical Center, University of Sarajevo, 71000 Sarajevo, Bosnia and Herzegovina.
Abstract:
(1) Background: This study investigates the effects of curing light intensity, exposure time, and distance on the Vickers microhardness (VMH), hardness bottom-to-top ratio (HR), and temperature rise (TR) of conventional dental resin-based composite (RBC). (2) Materials and Methods: Specimens of one conventional RBC (Tetric EvoCeram, Ivoclar Vivadent) were cured with 12 different curing protocols (CPs), created with three different light intensities (Quartz Tungsten Halogen 300 mW/cm2, LED 650 mW/cm2, LED 1100 mW/cm2), two exposure times (20 and 40 s), and two distances of curing tip (0 and 8 mm). The VMH of top (VMH-T) and bottom (VMH-B) surfaces was measured. The hardness bottom-to-top ratio (HR) was calculated from VMH-B and VMH-T. The HR below 80% was rated as inadequate polymerization. The TR at the depth of 2 mm within the RBC was measured using a K-type thermocouple. Data were analyzed using Levene's test and the multivariate analysis of variance (MANOVA). The level of significance was set at p < 0.05. (3) Results: Exposure time and distance significantly influenced VMH-B and HR. Increased distance significantly reduced VMH-B, HR, and TR. CPs 300 mW/cm2/8 mm/20 s and 650 mW/cm2/8 mm/20 s produced inadequate polymerization (HR < 80%). Prolonged exposure time produced higher values of VMH-B and HR. The TR was significantly influenced by light intensity and distance. (4) Conclusions: Suboptimal light intensity (<800 mW/cm2) can produce inadequate polymerization at the lower side of the composite layer when used from a distance. Prolonged irradiation can improve the polymerization to a certain extent. Clinicians are advised to monitor the intensity of the LCUs in order to optimize the photopolymerization process. Caution is required when polymerizing with high-intensity curing light in direct contact with the RBC with longer exposure times than recommended.
More Related Videos
Related Concept Videos
Polymer Classification: Stereospecificity
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...