Precise wavelength alignment of second-harmonic generation in thin-film lithium niobate resonators

Optics Letters
|November 27, 2024
PubMed

Related Concept Videos

Restarting Stalled Replication Forks02:37

Restarting Stalled Replication Forks

DNA replication is initiated at sites containing predefined DNA sequences known as origins of replication. DNA is unwound at these sites by the minichromosome maintenance (MCM) helicase and other factors such as Cdc45 and the associated GINS complex.The unwound single strands are protected by replication protein A (RPA) until DNA polymerase starts synthesizing DNA at the 5’ end of the strand in the same direction as the replication fork. To prevent the replication fork from falling apart,...
5.1K
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
1.3K
¹H NMR Signal Multiplicity: Splitting Patterns01:13

¹H NMR Signal Multiplicity: Splitting Patterns

When protons A and X are coupled, their nuclear spin energy levels are slightly modified. This is because the energy required to excite proton A to a spin state parallel to proton X is slightly different from the energy required for it to become anti-parallel to spin X. Consequently, there are two possible excitation frequencies for A (A1 and A2), depending on the spin state of X, and vice versa. The mutual nature of coupling implies that the difference between frequencies A1 and A2, indicated...
7.0K
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.7K
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
870