Related Experiment Video
Updated: Jun 6, 2025

Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Avoiding Unwanted Exposure of Subperiosteal Implants in the Atrophic Maxilla: Technical Note
Sergio Olate1,2,3, Alejandro Unibazo4, Victor Ravelo5
1Division of Oral and Maxillofacial Surgery, Universidad de La Frontera.
None:
The use of subperiosteal implants for the rehabilitation of atrophic maxillae has taken attention recently as a validated option in the treatment of severe atrophy. The systems have been improved by technological advancements and the analysis of variables affecting their prognosis. However, one of the most frequent issues to resolve is the unwanted exposure of a portion of the metal mesh close to the abutment and prosthetic connections, which can result in infections, hygiene problems, and, in some instances, complete failure. It seems that the surgical approach is a hot topic for the success of these implants. This article describes a surgical technique that lowers the risk of unintended implant exposure by enabling the subperiosteal implant to be installed from the lateral approach and enabling the right access to the prosthetic abutments in a transfixing way from palatal approach, away from the primary surgical access.