Allocation and validation of the second revision of the International Staging System in the ICARIA-MM and IKEMA

Paul G Richardson1, Aurore Perrot2, Joseph Mikhael3

  • 1Jerome Lipper Multiple Myeloma Center, Department of Medical Oncology, Dana Farber Cancer Institute, Harvard Medical School, Boston, MA, USA. paul_richardson@dfci.harvard.edu.

Blood Cancer Journal
|November 28, 2024
PubMed

The International Staging System for multiple myeloma recently underwent a second revision (R2-ISS) to include gain/amplification of 1q21 and account for the additive prognostic significance of multiple high-risk features. The phase 3 ICARIA-MM (isatuximab-pomalidomide-dexamethasone vs. pomalidomide-dexamethasone) and IKEMA (isatuximab-carfilzomib-dexamethasone vs. carfilzomib-dexamethasone) studies provide large datasets for retrospectively validating the prognostic value of the R2-ISS in relapsed/refractory multiple myeloma. Of 609 pooled patients, 68 (11.2%) were reclassified as R2-ISS stage I, 136 (22.3%) as R2-ISS stage II, 204 (33.5%) as R2-ISS stage III, 55 (9.0%) as stage IV, and 146 (24.0%) "Not classified". Median progression-free survival was shorter among those reclassified as R2-ISS stage II (HR 1.52, 95% CI 0.979-2.358), stage III (HR 2.59, 95% CI 1.709-3.923), and stage IV (HR 3.51, 95% CI 2.124-5.784) versus stage I. Adding isatuximab led to longer progression-free survival versus doublet therapy (adjusted HR 0.544 [95% CI 0.436-0.680]), with a consistent treatment effect observed across all R2-ISS stages. This is the first study to validate the R2-ISS with novel agents, including anti-CD38 monoclonal antibodies, and to show that R2-ISS, as a prognostic scoring system, can be applied to patients with relapsed/refractory multiple myeloma.

Related Concept Videos

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then passed on to...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.