Purpose:
This study evaluated the dose fall off and valley dose percentage in pelvic cancer Lattice Radiotherapy (LRT) using various treatment techniques.
Methods:
Forty five treatment plans were developed for 15 patients undergoing radiotherapy using a linear accelerator. Plans were categorized into three sets: RapidArc (RA), seven-field intensity-modulated radiation therapy (IMRT), and nine-field IMRT, both for high-dose (HD) vertices and the entire planning target volume (PTV). Dose fall-off indices were analyzed using the normalized dose fall-off index (ʌ) to compare the rate of dose decrease beyond HD vertices. Valley dose percentages were determined by analyzing dose profiles between HD vertices to quantify lower dose percentages. Analysis involved averaging normalized dose fall-off index (ʌ) values, valley dose percentages and grouping valley doses to assess variation with respect to center-to-center (CTC) intervals between HD vertices for all the techniques.
Results:
RA plans achieved sharper dose fall-off beyond HD vertices compared to seven-field and nine-field IMRT techniques, with decreasing values as distance from the central plane increased. RA plans also exhibited higher valley doses (62.05%) relative to nine-field IMRT (55.02%) and seven-field IMRT (56.56%) for an average CTC distance of 3.75 cm, showing significant variability across CTC intervals.
Conclusions:
RA plans achieve steeper dose fall-off and higher valley doses compared to IMRT, effective for pelvic LRT but less suitable for grid therapy due to challenges with MLCs. Minimal differences in valley doses between nine-field and seven-field IMRT suggest limited impact from beam angles, guiding treatment optimization. The equations derived can be utilized for dosimetric evaluation and clinical planning in grid therapy, emphasizing their practical relevance in treatment strategy development.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Drug Accumulation During Multiple Dosing: Repetitive IV Injections
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Dose Response Curve: Conventional Versus Nonmonotonic