Accelerated phase-contrast magnetic resonance imaging with use of resolution enhancement generative adversarial
Manuel A Morales1, Fahime Ghanbari1, Ömer Burak Demirel1
1Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA.
Background:
Cardiovascular magnetic resonance (CMR) phase contrast is used to quantify blood flow. We sought to develop a complex-difference reconstruction for inline super-resolution of phase-contrast flow (CRISPFlow) to accelerate phase-contrast imaging.
Methods:
CRISPFlow was built on the super-resolution generative adversarial network. The model was trained and tested (4:1 ratio) using retrospectively identified phase-contrast images from 2020 patients (56 ± 16 years; 1131 men) referred for clinical 3T CMR at a single center from 2018 to 2023. For testing, ascending aortic flow images collected with 2.5 × 1.9 mm2 resolution using generalized autocalibrating partially parallel acquisitions (GRAPPA) were used to synthesize images with 7.5 × 1.9 mm2 resolution. CRISPFlow subsequently restored spatial resolution. In a prospective validation study of 38 participants (57 ± 15 years; 14 men) and 16 healthy individuals (42 ± 16 years; 6 men), CRISPFlow was applied to phase-contrast images collected with 7.5 × 1.9 mm2 resolution with use of GRAPPA and was compared to GRAPPA-accelerated images collected with 2.3 × 1.9 mm2 resolution. A blur metric was used to quantify sharpness. Aortic flow measurements were obtained semi-automatically. Statistical evaluation included analysis of variance, Bland-Altman analysis, and Pearson correlation coefficient (r).
Results:
CRISPFlow reconstruction was successful in all cases. CRISPFlow reduced blurring in retrospective (0.35 vs 0.47, P < 0.001) and prospective (0.34 vs 0.48, P < 0.001) images with 7.5 × 1.9 mm2 resolution. Blurring in CRISPFlow images was similar to blurring in images with 2.5 × 1.9 mm2 (0.35 vs 0.35, P = 0.4082) and 2.3 × 1.9 mm2 (0.34 vs 0.32, P < 0.001) resolution. Bland-Altman differences in forward volume (-2 mL [-8 to 3 mL]), regurgitant volume (0 mL [-3 to 2 mL]), and a fraction (0% [-5 to 4%]) showed good agreement between the two techniques in a retrospective cohort. Differences in forward volume (1 mL [-11 to 14 ml]) also showed good agreement in the prospective cohort. There was a strong correlation (all r > 0.90) between GRAPPA and CRISPFlow measurements of flow in both studies.
Conclusion:
We demonstrated the potential of CRISPFlow to accelerate phase contrast CMR.
Related Concept Videos
Magnetic Resonance Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...