Exploring the dosimetric impact of systematic and random setup uncertainties in robust optimization of head and neck
Suresh Rana1, Noufal Manthala Padannayil1, Youssef Zeidan1
1Department of Radiation Oncology, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Boca Raton, FL, USA.
Purpose:
This study aims to compare the dosimetric impact of incorporating systematic and random setup uncertainties in the robust optimization of head and neck cancer (HNC) Intensity Modulated Proton Therapy (IMPT) plans.
Methods:
Bilateral HNC patients (n = 10) previously treated with conventional photon therapy at our institution were included. Both systematic and random setup uncertainties were incorporated into the robust optimization process of IMPT planning. Dosimetric comparisons were made between plans optimized with systematic (IMPT-S) versus random (IMPT-R) setup uncertainties, assessing both the clinical target volume (CTVs) and organs at risk (OARs) across various dosimetric metrics. Both plans applied a fixed range uncertainty of ± 3 % and a maximum setup uncertainty of ± 3 mm.
Results:
Both IMPT-S and IMPT-R plans achieved similar target coverage, meeting robustness criteria for CTVs. On average, the D95% voxel-wise min to the high-risk CTV (CTV_HR) was slightly higher in IMPT-S plans by 1.78 ± 0.72 % compared to IMPT-R plans. However, IMPT-R plans provided better OAR sparing, which was evident in both nominal and voxel-wise maximum values. While random setup errors in robust optimization improved OAR sparing, the clinical impact may be minimal where OAR doses are already well below tolerance levels.
Conclusion:
Both IMPT-S and IMPT-R techniques met the robustness criteria for CTVs in HNC IMPT planning. Incorporating random setup uncertainties in robust optimization improves OAR sparing compared to systematic setup uncertainties. Further research is needed to explore the broader applicability of random setup errors and to integrate random uncertainties in robustness evaluations for a more comprehensive assessment of treatment plans.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Dosage Regimen: Individualization
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Pharmacokinetic–Pharmacodynamic Relationship: Problems
Impact of Pharmacokinetic–Pharmacodynamic Models: Regulatory Decisions
Methods of Medium Optimization