Carbon Nanotube-Based Chemiresistive Sensor Array for Dissolved Gases
Thomas Kirby1, Md Ali Akbar1, Mehraneh Tavakkoli Gilavan2
1Department of Chemistry and Chemical Biology, McMaster University, 1280 Main St. W., Hamilton, Ontario L8S 4M1, Canada.
Abstract:
Dissolved gases such as oxygen (DO) and ammonia (dNH3) are among the most consequential parameters for the assessment of water quality. Since the concentrations of DO and dNH3 are interdependent through the nitrogen cycle, simultaneous monitoring can be useful in many applications. For example, in wastewater treatment, aeration baths are used to adjust the rate of removal of ammonia by the bioactive sludge. Here, we have developed a sensing array which can monitor dissolved molecular oxygen (DO) and dissolved un-ionized ammonia (dNH3) continuously and simultaneously. This was achieved by functionalizing two sensors made from single-walled carbon nanotube (SWCNT) films with two different molecules: phenyl-capped aniline tetramer (PCAT) and iron phthalocyanine (II) (FePc). It was found that the FePc-doped SWCNT (FePc@SWCNT) sensors demonstrated good sensitivity and selectivity to DO, compared to dNH3. Conversely, we found that the PCAT-doped SWCNT (PCAT@SWCNT) sensors demonstrate greater sensitivity to ammonia. Investigating the effect of different PCAT salts as a dopant, we describe the following series of sensor responses to ammonia: chloride < crotonate < fumarate. Additionally, we coated our sensors with thin PDMS membranes, which are selectively permeable to gases, over ionic species. Finally, using principal component analysis (PCA) and partial least-squares discriminant analysis, it was possible to discriminate between responses to DO and dNH3, with 100% accuracy. As a result, here, we have developed a compelling proof-of-concept for the use of a single sensing substrate, doped with molecules with distinct mechanisms of interaction with two different analytes, to simultaneously monitor concentrations of two dissolved gases, in this example, DO and dNH3.
More Related Videos
09:28Engineering Molecular Recognition with Bio-mimetic Polymers on Single Walled Carbon Nanotubes
Published on: January 10, 2017
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...