Colorimetric Determination of Dissolved Oxygen: Assessment of Methodological Influences on Iodine Spectra, Isosbestic
Su-Cheng Pai1, Cheng-Ho Li1, Brandon M Stephens1
1Institute of Oceanography, National Taiwan University, 1 Section 4 Roosevelt Road, Taipei 106319, Taiwan.
Abstract:
The colorimetric method for determining dissolved oxygen concentrations in freshwater and seawater samples essentially relies on measuring the absorbance of released I2 and I3 - in a mixed form. While this approach is relatively quick and convenient, it is susceptible to significant temperature effects during analysis, irrespective of field temperatures. Additionally, the influences of spectrophotometric absorbance wavelengths and iodine concentrations on oxygen concentration determinations are ambiguous. We found that, while iodine concentration and absorbance wavelength impart minor influences, temperature changes during sample analysis alter the fractionation of two major iodine species (I2 and I3 -) and affect their spectra, with the latter effect imparting the greatest influence on oxygen concentrations. An empirical molar extinction coefficient was defined for the mixture (consisting of 96% I3 - and 4% I2), yielding values of 2282, 1115, and 792 M-1 cm-1 at 25 °C at the most commonly used wavelengths of 430, 456, and 466 nm, respectively. Altering the temperature led to variances in absorbance by 0.33%, 0.42%, and 0.51% °C-1 at 430, 456, and 466 nm, respectively. Therefore, for absorbances measured at 456 nm, a room temperature correction can be applied to the empirical molar coefficient by 1115 M-1 cm-1 × [1 + (room temperature - 25 °C) × 0.0042]. Reducing room temperature differences between samples and calibration solutions became the most important factor in maintaining the precision and accuracy of the measurement. With these precautions, a precision of ∼0.2% (coefficient of variation) over the normal surface water oxygen concentration of around 250 μM can be readily achieved at all tested wavelengths. This method offers a linear oxygen concentration range of 0-650 μM.
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Redox Titration: Overview
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Flame Photometry: Lab
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Measuring Reaction Rates