Long-Term Outcomes of EUS-Guided Gastroenterostomy: A Large, Single-Center Experience
Judy A Trieu1, Sam Kahlenberg2, Andrew J Gilman1
1Division of Gastroenterology and Hepatology, University of North Carolina, Chapel Hill, North Carolina, USA.
Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) shows promising long-term outcomes with low adverse events. Regular stent exchange in EUS-GE patients requiring long-term access can prevent complications.
Area of Science:
- Gastroenterology
- Interventional Endoscopy
- Surgical Oncology
Background:
- Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is an established procedure for both benign and malignant conditions.
- Limited data exists regarding the long-term outcomes and stent-related adverse events (AEs) following EUS-GE.
- This study aims to evaluate the long-term results and safety profile of EUS-GE.
Purpose of the Study:
- To assess the long-term outcomes of patients undergoing EUS-GE.
- To identify and analyze stent-related adverse events (AEs) associated with EUS-GE.
- To evaluate the efficacy of EUS-GE in various clinical scenarios.
Main Methods:
- Retrospective analysis of 207 patients who underwent EUS-GE between January 1, 2014, and December 31, 2022, at a tertiary care institution.
- Inclusion of patients with both benign and malignant indications for EUS-GE.
- Follow-up of patients for at least 3 months post-procedure to record outcomes and AEs.
Main Results:
- High technical success rate of 95.7% in 207 patients (56.5% malignant, 43.5% benign indications).
- Mean follow-up of 406 days; 63.6% of stents remained in place for ≥3 months, and 21% for ≥1 year.
- Late AEs occurred in 3.4% of patients; no late AEs were observed in stent-dependent patients with annual stent exchanges.
Conclusions:
- EUS-GE demonstrates favorable long-term outcomes with a low incidence of adverse events.
- Proactive annual stent exchange is recommended for patients requiring long-term EUS-GE to prevent complications like stent delamination and occlusion.
- EUS-GE is increasingly valuable for accessing the gastrointestinal tract in cases of altered anatomy, gastric outlet obstruction (GOO), and as a bridge to surgery.
More Related Videos
09:40An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
03:32Single Incision Plus One Port Laparoscopic Proximal Gastrectomy with Double Channel Anastomosis for Gastric Cancer Treatment
Published on: December 27, 2024
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Enteral Nutrition II: Nasointestinal and Gastrostomy Feeding
Nasointestinal Feeding
Nasointestinal feeding involves placing a tube...
Endoscopic Procedures V: ERCP
Patient...
Peptic Ulcer Disease V: Surgical Management and Nursing Care
Surgical Interventions for Peptic Ulcer Disease
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...