Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Investigation of organs dosimetry precision using ATOM phantom and optically stimulated luminescence detectors in
Abdellah Khallouqi1, Hamza Sekkat1, Omar El Rhazouani1
1Laboratory of Health Sciences and Technologies, Higher Institute of Health Sciences, Hassan 1st University, Settat, Morocco.
Abstract:
The primary objective of this study was to compare organ doses measured using optically stimulated luminescent dosimeters (OSLDs) with those estimated by the CT-EXPO software for common CT protocols. An anthropomorphic ATOM phantom was employed to measure organ doses across head, chest, and abdominal CT scans performed on a Hitachi Supria 16-slice CT scanner. These OSLD measurements were then compared to the estimates provided by the widely used CT-EXPO software. Organ doses were assessed using OSLDs placed in an adult anthropomorphic phantom, with calibration performed through a comprehensive process involving multiple tube potentials and sensitivity corrections. Results from three CT acquisitions per protocol were compared to estimates provided by CT-EXPO software. Findings reveal significant discrepancies between measured and estimated organ doses, with p-values consistently below 0.05 across all organs. For head CT, measured eye lens doses averaged 33.51 mGy, 6.0% lower than the estimated 35.65 mGy. In chest CT, the thyroid dose was 9.82 mGy, 13.5% higher than the estimated 8.65 mGy. For abdominal CT, the liver dose measured 12.11 mGy, 9.6% higher than the estimated 11.05 mGy. Measured doses for the rest of organs were generally lower than those predicted by CT-EXPO, showing some limitations in current estimation models and the importance of precise dosimetry. This study highlights the potential of OSLD measurements as a complementary method for organ dose assessment in CT imaging, emphasizing the need for more accurate organ dose measurement to optimize patient care.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...