Related Experiment Video
Updated: May 2, 2026

Extracting Visual Evoked Potentials from EEG Data Recorded During fMRI-guided Transcranial Magnetic Stimulation
Published on: May 12, 2014
Stimulation artefact removal: review and evaluation of applications in evoked responses
Tianshu Zhang1, Kiaran Lawson1, Wee-Lih Lee2,3
1Deep Brain Stimulation Technologies Pty Ltd, East Melbourne, Australia.
Abstract:
Objective.This study investigated software methods for removing stimulation artefacts in recordings undertaken during deep brain stimulation (DBS). We aimed to evaluate artefact attenuation using sample recordings of evoked resonant neural activity (ERNA), as well as a synthetic ground-truth waveform that emulated observed ERNA characteristics.Approach.The synthetic waveform and eight raw DBS recordings were processed by fourteen algorithms spanning the following categories: signal modification, signal decomposition, and template subtraction. For the synthetic waveform, performance was quantified by comparing each reconstructed signal against the ground-truth waveform. For DBS recordings, performance was contrasted amongst each other. The stimulation artefact was quantified by its amplitude and subsequent decay to baseline by the time to first zero-crossing. Each reconstructed ERNA signal was characterised by peak-to-peak-amplitude, root-mean-square amplitude, latency, and number of zero-crossings.Main results.None of the methods performed overall as well as the Backward Filter. Signal decomposition techniques were able to attenuate stimulation artefact albeit with unacceptable ERNA distortion.Significance.Upon evaluation of common software methods for DBS artefact attenuation, we advocate the use of the Backward Filter for reducing such artefacts while reconstructing ERNA.
More Related Videos
08:43Combined Shuttle-Box Training with Electrophysiological Cortex Recording and Stimulation as a Tool to Study Perception and Learning
Published on: October 22, 2015
08:23A Multimodal Imaging- and Stimulation-based Method of Evaluating Connectivity-related Brain Excitability in Patients with Epilepsy
Published on: November 13, 2016
Related Concept Videos
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Mutagenicity and Carcinogenicity
Modified-Release Drug Delivery Systems: Stimuli-Activated
Toxicity Testing in Animals