Reliability of a portable toe pressure photoplethysmography device compared to a stationary laser doppler flowmeter
Perttu Laamanen1, Mirjami Laivuori1, Katariina Noronen1
1Department of vascular surgery, University of Helsinki and Helsinki University Hospital, Helsinki, Finland.
Abstract:
ObjectiveThe study aimed to investigate the reliability of a portable toe pressure (TP) photoplethysmography device (PPG) by comparing it to a stationary laser Doppler flowmeter (LD) used in the Helsinki University Hospital. The study evaluated if lower limb arterial circulation could be reliably evaluated with the portable PPG which is more affordable and mobile than the stationary LD.MethodsTPs were measured from 102 toes of 54 patients in the vascular surgery outpatient clinic, vascular surgery ward and interventional radiology recovery ward of Helsinki University Hospital. According to the study protocol TPs were measured twice with the PPG device. If the difference between the values was over 10 mmHg, a third measurement was done and two of the closest values were selected for the final analysis. The lowest value displayed by the PPG device was 30 mmHg. Lower than 30 mmHg values were reported as 25 mmHg in the analysis. The repeatability and reliability of the PPG measurements were compared to the LD with Bland Altman plots.ResultsMost patients had rest pain (n = 29) or claudication (n = 9). Prior to TP measurement, 24 patients had undergone lower limb revascularization through either a hybrid (n = 3), open (n = 10) or endovascular (n = 11) procedure. The mean absolute difference between PPG and LD measurement values was 15 mmHg (95% confidence interval 12-18 mmHg). 87.5% of lower limbs with significant arterial insufficiency (TP <60 mmHg with LD, n = 49) had a PPG measurement value of <60 mmHg. Conversely, 84.8% of lower limbs that did not exceed the ischemia criterion of TP ≥60 mmHg with LD had a PPG measurement value of ≥60 mmHg. Mean absolute difference of two consecutive PPG measurement values was 4 mmHg (95% CI 3-5 mmHg).ConclusionsThe PPG device is a light and affordable option for the assessment of lower limb arterial circulation in primary health care. It is moderately reliable to exclude significant lower limb arterial insufficiency and may reduce unnecessary referrals to the vascular surgery clinic. The repeatability of the PPG device is satisfactory. However, it requires training to use, and the results must always be interpreted with consideration for the patient's clinical status.
More Related Videos
10:39Laser Doppler: A Tool for Measuring Pancreatic Islet Microvascular Vasomotion In Vivo
Published on: March 8, 2018
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: