Related Experiment Video
Updated: Jun 5, 2025

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Changes in central venous pressure during a fluid challenge have limited value for guiding fluid therapy
Priscilla Souza de Oliveira1, Fernando José da Silva Ramos1, Daniere Yurie Vieira Tomotani1
1Department of Anesthesiology, Pain and Intensive Care Medicine, Escola Paulista de Medicina, Universidade Federal de São Paulo - São Paulo (SP), Brazil.
Objective:
To evaluate whether changes in central venous pressure during fluid expansion and baseline cyclic respiratory variation in the central venous pressure amplitude (RespCVP) curve could be used to discriminate between fluid responders and nonresponders.
Methods:
This prospective observational study included critically ill adult patients who underwent fluid expansion in the form of a fluid bolus or fluid challenge with crystalloids. All patients were under mechanical ventilation and adequately sedated. We determined the central venous pressure at baseline (CVPT0) and the changes at 5 (ΔCVPT5), 10 (ΔCVPT10) and 15 (ΔCVPT15) minutes during fluid infusion. We also measured the RespCVP at baseline. Fluid responsiveness was defined as a cardiac index increase of ≥ 15%.
Results:
The study included 30 patients (11 responders and 19 nonresponders). The CVPT0 and the changes after a fluid challenge at all three time points did not adequately predict fluid responsiveness, as determined by their area under the curve values (CVPT0: 0.70, (95%CI: 0.49 - 0.90; ΔCVPT5: 0.78, (95%CI: 0.57 - 0.99; ΔCVPT10: 0.63, (95%CI: 0.39 - 0.88; ΔCVPT15: 0.68, ((95%CI: 0.45 - 0.92). The RespCVP at baseline also had a poor performance (area under the curve: 0.70; 95%CI: 0.50 - 0.91).
Conclusion:
Changes in central venous pressure have limited value in predicting fluid responsiveness.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Parentral Nutrition: Centeral and Peripheral Parental Nutrition
PN can be administered through two primary routes:
1. Central Parenteral Nutrition (CPN):
CPN involves delivering a high concentration of nutrients through a large vein. This is typically achieved using a Peripherally Inserted Central Catheter (PICC) or,...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Body Water Content and Fluid Compartments
Fluid Movement Between Compartments