Diagnostic Performance of Artificial Intelligence-Based Angiography-Derived Non-Hyperemic Pressure Ratio Using
Hiroyuki Omori1,2, Yoshiaki Kawase1, Takuya Mizukami1,3
1Department of Cardiovascular Medicine, Gifu Heart Center.
Background:
The angiography-derived non-hyperemic pressure ratio (angioNHPR) is a novel index of NHPR based on artificial intelligence (AI) that does not require pressure wires. We investigated the diagnostic accuracy of angioNHPR for detecting hemodynamically relevant coronary artery disease.
Methods And Results:
In this retrospective single-center study, angioNHPR was assessed using the invasive NHPR as the reference standard. An angioNHPR ≤0.89 was defined as indicative of physiologically significant stenosis. Two angiographic projections ≥30° difference in angulation were selected. The lumen and centerline were automatically segmented by the prototype software, allowing for the calculation of the angioNHPR. We assessed 222 vessels from 178 patients. The accuracy of angioNHPR was 76.6% (95% confidence interval [CI] 70.4-82.0), with sensitivity 66.2% (95% CI 54.0-77.0), specificity 81.5% (95% CI 74.3-87.3), positive predictive value 62.7% (95% CI 53.6-70.9), and negative predictive value 83.7% (95% CI 78.6-87.7). The angioNHPR showed good correlation with invasive NHPR (r=0.72; 95% CI 0.64-0.77; P<0.001), and the agreement between angioNHPR and invasive NHPR was -0.01 (limits of agreement: -0.13, 0.11). The area under the curve (AUC) of angioNHPR was 0.81 (95% CI 0.75-0.86), which was significantly higher than that of 2-dimensional quantitative coronary angiography (AUC 0.69; 95% CI 0.62-0.75; P=0.007).
Conclusions:
AI-based angioNHPR demonstrates good diagnostic performance using invasive NHPR as the reference standard.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure